1983
DOI: 10.1016/s0003-4975(10)61548-2
|View full text |Cite
|
Sign up to set email alerts
|

Graft Replacement of the Thoracic Aorta with a Sutureless Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
2

Year Published

1985
1985
2004
2004

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(6 citation statements)
references
References 7 publications
0
4
0
2
Order By: Relevance
“…The true lumen was measured, and an appropriately sized preclotted ringed graft was inserted as described previously. 4,8 The proximal spool was introduced into the aortic lumen, and the graft was positioned in the desired location. The nylon tape was tied over the aorta, overlying the groove in the ring without constriction of the lumen.…”
Section: Surgical Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…The true lumen was measured, and an appropriately sized preclotted ringed graft was inserted as described previously. 4,8 The proximal spool was introduced into the aortic lumen, and the graft was positioned in the desired location. The nylon tape was tied over the aorta, overlying the groove in the ring without constriction of the lumen.…”
Section: Surgical Proceduresmentioning
confidence: 99%
“…[3][4][5][6][7][8][9][10][11] The sutureless intraluminal aortic graft has been used for acute type A aortic dissection, with the advantages of decreasing the graft insertion time and preventing the difficulties inherent in suturing to friable and diseased aortic tissue. However, Séguin et al 12 reported that using the intraluminal sutureless graft for replacement of the ascending aorta in acute aortic dissections resulted in a high rate of surgical complications in the short term.…”
Section: Introductionmentioning
confidence: 99%
“…eoro nary ostia with the help of Prolene sutures as mentioned above. Some authors eonsider this procedure to be op• tional ( 1) and some obligato ry (3). The proximal ring was then fixed to the aortie wall by the tap e provided for th is purpose.…”
Section: Surgica/ Techniquementioning
confidence: 99%
“…Porém, o tratamento conservador não impede o crescimento da falsa luz nem a isquemia de órgãos abdominais e membros inferiores levando a uma mortalidade em 5 anos de 65% (7,8) . Houve, nos anos seguintes, o desenvolvimento de novas técnicas cirúrgicas, como a de BORST et al (9) "tromba de elefante", a cola biológica (10) ,as próteses intraluminais sem sutura (11)(12)(13) e, por fim, as próteses intraluminais percutâneas (14) expandidas por balão (15) e auto-expansíveis (16) .…”
Section: Introductionunclassified