The patent false lumen influences postoperative aortic enlargement. However, with careful follow-up, a favorable prognosis is expected even for patients with a residual patent false lumen.
Electrode performances of MgH2-LiBH4 composite materials for lithium-ion batteries have been studied using LiBH4 as the solid-state electrolyte, which shows a high reversible capacity of 1650 mA h g(-1) with an extremely low polarization of 0.05 V, durable cyclability and robust rate capability.
For many years, it was thought that nonpulsatile perfusion produced physiological and circulatory abnormalities. Since 1977, Yukihiko Nosé and his colleagues have challenged this misconception. Toward that end, they did show that if a 20% higher blood flow uses more than that required for a pulsatile blood pump, then there would be no circulatory of physiological abnormalities. These experimental findings confirm that there is no difference in clinical outcome using either a pulsatile or nonpulsatile blood pump. Furthermore, the nonpulsatile rotary blood pump demonstrates efficient and reliable performance in various clinical situations. The nonpulsatile blood pump is a simple and reliable design that is manufactured easily and that has several desirable features. There is no need to incorporate heart valves, which are the most thrombogenic and blood trauma-inducing components. A continuous flow pump does not require a large orifice inflow conduit and proves to be easier to implant in patients with minimal damage to the myocardium. There is no need to incorporate a compliance volume-shifting device, which is essential for a pulsatile blood pump. The nonpulsatile device is a continuous blood pumping system; therefore, the control system is simpler and more reliable than that of a pulsatile pump. Because of the rotary blood pump's structure, only one moving part is necessary for the blood-pumping motion. By using durable components for this moving part, a durable system becomes possible. Because the electrical motor operates continuously, the on-and-off motion required for a pulsatile pump is not necessary; therefore, it is a more efficient and durable system. Thus, this group is working on the development of a nonpulsatile blood pump as a permanently implantable assist device. To achieve this goal, it is necessary to incorporate seven features into the system: small size, atraumatic features, antithrombogenic features, antiinfection features, a simple and durable design, and low energy requirement with easy controllability.
The anode properties of pristine MgH2 and MgH2 catalyzed with Nb2O5 have been investigated for an all solid-state lithium-ion battery. The catalytic effect stabilizes the plateau voltage as a result of kinetic improvement of the hydrogen transfer from the Mg phase to the Li phase.
Fulminant pulmonary embolism (PE) with circulatory collapse is associated with a high mortality rate due to acute right ventricular failure and hypoxia. Immediate and appropriate resuscitation and circulatory support in the perioperative period is mandatory to prevent sudden death. Extracorporeal membrane oxygenation (ECMO) was recently introduced for extracorporeal life support in patients with circulatory collapse and has provided an excellent outcome. We report on the effectiveness of ECMO support for fulminant PE. Seven patients were placed on veno-arterial ECMO for circulatory collapse caused by fulminant PE refractory to conventional treatment. After resuscitation, all patients underwent pulmonary angiography, and thrombolytic therapy was administered in all 7 patients under ECMO support. Three patients who did not improve by thrombolysis underwent embolectomy with standard cardiopulmonary bypass. Two thrombolysis and 2 surgery patients were weaned from bypass and survived. The duration of support ranged from 18-168 h (mean = 67.8 +/- 67.1 h), with maximum bypass flow rates of 2.0-4.5 (mean = 3.5 +/- 0.9). There were no device-related complications during support. In total, 4 patients (57%) were successfully weaned from support and discharged from the hospital in good condition. All patients who survived required prolonged support (27, 82, 151, and 168 h). We conclude that resuscitation and circulatory support using ECMO can be effective, life-saving measures in cases of circulatory collapse caused by fulminant PE.
Two well-known centrifugal and axial pumping principles are used simultaneously in a new blood pump design. Inside the pump housing is a spiral impeller, a conically shaped structure with threads on the surface. The worm gears provide an axial motion of the blood column through the threads of the central cone. The rotational motion of the conical shape generates the centrifugal pumping effect and improves the efficiency of the pump without increasing hemolysis. The hydrodynamic performance of the pump was examined with a 40% glycerin-water solution at several rotation speeds. The gap between the housing and the top of the thread is a very important factor: when the gap increases, the hydrodynamic performance decreases. To determine the optimum gap, several in vitro hemolysis tests were performed with different gaps using bovine blood in a closed circuit loop under two conditions. The first simulated condition was a left ventricular assist device (LVAD) with a flow rate of 5 L/min against a pressure head of 100 mm Hg, and the second was a cardiopulmonary bypass (CPB) simulation with a flow rate of 5 L/min against 350 mm Hg of pressure. The best hemolysis results were seen at a gap of 1.5 mm with the normalized index of hemolysis (NIH) of 0.0063 +/- 0.0020 g/100 L and 0.0251 +/- 0.0124 g/100 L (mean +/- SD; n = 4) for LVAD and CPB conditions, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.