SUMMARY The prevalence of coronary artery stenoses 2 70% or left main stenosis > 50% was evaluated in 20,391 patients who underwent angiography in the Coronary Artery Surgery Study from 1975-1979. After the patients with unstable angina or myocardial infarction were excluded, the disease prevalence in the 8157 patients with definite angina, probable angina, and nonspecific chest pain was 93%, 66% and 14% in men and 72%, 36% and 6% in women (p < 0.001).The age and sex of the patients and character of chest pain were important determinants of disease prevalence and severity. Left main or three-vessel coronary disease occurred in more than 50% of middle-aged men and older women with definite angina and in more than 50% of men who had probable angina and were older than 60 years of age. In contrast, left main coronary disease occurred in less than 2% of 1282 men and less than 1% of 1397 women with nonspecific chest pain regardless of age. In this latter patient subset, less than 5% of men and less than 1% of women in each decade under 60 years had left main or three-vessel coronary artery disease.Thus, high-risk coronary disease is common in middle-aged patients with definite angina and older patients with probable angina, but is rare in patients with nonspecific chest pain. Indications and guidelines for diagnostic noninvasive tests and coronary angiography could be based on these results.
Hypothesis:A bioabsorbable tissue scaffold of porcine submucosal small intestine extracellular matrix (Surgisis Gold [SIS]; Cook Biotech Inc, West Lafayette, Ind) mesh is safe and effective for ventral hernia repair.Design: Retrospective case series at a university teaching hospital.Patients: Fifty-three consecutive patients having 8-ply SIS mesh repair of ventral abdominal hernias.
Main Outcome Measures:Early complications, reoperation, hernia recurrence, mesh or wound infection, or reaction. Outcomes reported and compared on an intention-to-treat basis.Results: Patients were stratified by wound class: clean, clean-contaminated and contaminated, or dirty. Median follow-up was 14 months (range, 2-29 months) during which there were 22 complications (41%), 17 early reoperations (32%), 13 partial dehiscences (21%), 6 mesh re-
The favorable inter- and intraobserver agreements among 23 pulmonologists using dynamic flexible bronchoscopy to estimate the degree of dynamic central airway collapse provide additional evidence that dynamic flexible bronchoscopy is a reliable diagnostic tool for tracheobronchomalacia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.