2019
DOI: 10.1109/access.2019.2898881
|View full text |Cite
|
Sign up to set email alerts
|

Gas Sensor Array Dynamic Measurement Uncertainty Evaluation and Optimization Algorithm

Abstract: Metal oxide semiconductor (MOS) gas sensor array dynamic measurement uncertainty evaluation, which currently mainly uses static measurement approximation estimations, cannot accurately distinguish the measured value of the sudden change of the measured value caused by the dynamic mutation of the measured gas or the actual sensor array local fault caused by the sudden change of the measured value, thereby resulting in a dynamic measurement process of the MOS gas sensor array uncertainty evaluation results and t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 24 publications
(35 reference statements)
0
6
0
Order By: Relevance
“…The inaccuracy of outdoor low-cost gas sensors is mainly due to their stability, sensitivity, cross-sensitivities and weather conditions [24], [33]- [38]. Consequently, to overcome these problems, sophisticated calibration methods were developed such as neural networks and machine-learning methods.…”
Section: Related Workmentioning
confidence: 99%
“…The inaccuracy of outdoor low-cost gas sensors is mainly due to their stability, sensitivity, cross-sensitivities and weather conditions [24], [33]- [38]. Consequently, to overcome these problems, sophisticated calibration methods were developed such as neural networks and machine-learning methods.…”
Section: Related Workmentioning
confidence: 99%
“…where V Jn and d J are the entries of matrices V and -1 V -1 D respectively; λ n is the eigenvalue value of B. Substituting (12) into (7) and the effective isobaric specific heat of hydrogen becomes:…”
Section: Decoupled Expression Of Effective Specific Heat Of Hydrogenmentioning
confidence: 99%
“…Resolution refers to a ratio between the maximum magnitudes measured to the smallest part that can be determined. At the same time, accuracy is defined as the amount of uncertainty in measurement with respect to an absolute standard, and it can directly influence the qualitative analysis of the sensor [ 6 ]. Whereas the limit of detection (LOD) is the lowest quantity of a substance that can be distinguished by the sensor, wherein the capability of a sensor to identify a particular substance.…”
Section: Introductionmentioning
confidence: 99%