2012
DOI: 10.1016/j.nimb.2011.11.022
|View full text |Cite
|
Sign up to set email alerts
|

FTIR analysis of polyethylene terephthalate irradiated by MeV He+

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(25 citation statements)
references
References 35 publications
0
20
0
Order By: Relevance
“…. The characteristic peaks in the FTIR spectrum of the pristine PET nanofibers appeared at 1721 (CO stretching), 1413 (CC stretching and CH in plane deformation in aromatic ring), 1339 (CH 2 wagging) and 1246 (OCC stretching of ester), 1102 (OCH 2 stretching) and 1027 (ring CH in‐plane bending), 871 (parasubstituted benzen ring) and 729 cm −1 (CC bending and CH out of plane in aromatic ring) . The characteristic peak of coupled CC/CO stretching vibrations and the antisymmetric stretching vibration of the COC glycosidic bridge of CD could not be identified in the FTIR spectra of PET/CD nanofibers because of the overlapping of absorption peaks of CD and PET.…”
Section: Resultsmentioning
confidence: 99%
“…. The characteristic peaks in the FTIR spectrum of the pristine PET nanofibers appeared at 1721 (CO stretching), 1413 (CC stretching and CH in plane deformation in aromatic ring), 1339 (CH 2 wagging) and 1246 (OCC stretching of ester), 1102 (OCH 2 stretching) and 1027 (ring CH in‐plane bending), 871 (parasubstituted benzen ring) and 729 cm −1 (CC bending and CH out of plane in aromatic ring) . The characteristic peak of coupled CC/CO stretching vibrations and the antisymmetric stretching vibration of the COC glycosidic bridge of CD could not be identified in the FTIR spectra of PET/CD nanofibers because of the overlapping of absorption peaks of CD and PET.…”
Section: Resultsmentioning
confidence: 99%
“…Characterization studies: Fourier transform infrared (FTIR) spectroscopy was extensively used to study the environment of chemical bonds of polymers and the supramolecular interactions between molecules through the characterization of their vibrational types [14][15][16][17][18][19][20]. FTIR spectroscopic study of the polymer was conducted to ascertain the active functional groups on the polymer accountable for attaching of Pb 2+ from solution.…”
Section: Resultsmentioning
confidence: 99%
“…[16]. Numerous studies of PET samples irradiated by noble gases [17][18][19][20][21][22], metals [23][24][25] and nonmetals [2,26] were reported. In most cases a very prominent decrease of PET resistance with the implantation fluence was shown.…”
Section: Introductionmentioning
confidence: 99%