2013
DOI: 10.1007/978-3-642-37006-9_3
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence and Phosphorescence Chemical Sensors Applied to Water Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 101 publications
0
7
0
Order By: Relevance
“…This approach is similar to the one used by Sharma et al [326] to evaluate As and E. coli contamination in the India River via bioluminescent bio-reporter. For more details about the light emission spectroscopy via an optical fibre sensor platform, one can refer to the work conducted by Ibanez et al [327] and Chong et al [328].…”
Section: Light Emission/luminescence Spectroscopymentioning
confidence: 99%
“…This approach is similar to the one used by Sharma et al [326] to evaluate As and E. coli contamination in the India River via bioluminescent bio-reporter. For more details about the light emission spectroscopy via an optical fibre sensor platform, one can refer to the work conducted by Ibanez et al [327] and Chong et al [328].…”
Section: Light Emission/luminescence Spectroscopymentioning
confidence: 99%
“…In this configuration, the analyte is retained by adsorption either on a plane surface or in microbeads. In plane surfaces it is usual to deliver the analyte through the spotting of a few microliters of the sample in the support with the aid of micropipets, or through a solid-phase extraction procedure (Ibañez and Escandar, 2013). In the latter case, the active support is a membrane loaded into a stainless steel filter holder; applying a positive pressure with a syringe the sample solution is forced to pass through the disk.…”
Section: Solid-phase Spectroscopy In Batch Configurationmentioning
confidence: 99%
“…When particulate materials are used in batch configurations, equilibrium is established between microbead active sites and the analyte. After either evaporating or filtering the solution in which the components were dissolved, beads are transferred to a specially designed spectrofluorimetric holding for the corresponding measurement (Ibañez and Escandar, 2013).…”
Section: Solid-phase Spectroscopy In Batch Configurationmentioning
confidence: 99%
“…They offer a spectrum of advantages including immunity to electrical interference, high sensitivity and cost effectiveness [1], [2]. In the class of optical sensing technologies, fiber optic sensors deserve special mention for their added positives including remote sensing, lower weight, compact nature etc [3].…”
Section: Introductionmentioning
confidence: 99%