2012
DOI: 10.3390/s121114968
|View full text |Cite
|
Sign up to set email alerts
|

Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode

Abstract: A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 28 publications
(55 reference statements)
0
11
0
Order By: Relevance
“…A great deal of the published material involves the use of the NaPh 4 B (or related salts) as an additive, [20][21][22][23][24][25]28,29,31,[34][35][36][37][38][39]41,43,44,[46][47][48][49][50][51][52][66][67][68][69][70][71][72][73][74][75] which as shown in this paper interacts with Hg(II) and this has implications on the characteristics reported for these electrodes. In the absence of fundamental studies, the response of the electrode may result from the response of the additive rather than the ionophore (this may be occurring in the prior studies mentioned).…”
Section: Advantages Of the Cpa Based Ise Relative To Existing Ionophomentioning
confidence: 99%
See 1 more Smart Citation
“…A great deal of the published material involves the use of the NaPh 4 B (or related salts) as an additive, [20][21][22][23][24][25]28,29,31,[34][35][36][37][38][39]41,43,44,[46][47][48][49][50][51][52][66][67][68][69][70][71][72][73][74][75] which as shown in this paper interacts with Hg(II) and this has implications on the characteristics reported for these electrodes. In the absence of fundamental studies, the response of the electrode may result from the response of the additive rather than the ionophore (this may be occurring in the prior studies mentioned).…”
Section: Advantages Of the Cpa Based Ise Relative To Existing Ionophomentioning
confidence: 99%
“…Optimal working conditions for the potentiometric response of the electrode in terms of its membrane composition and the pH of the aqueous solution were investigated together with the characteristics of this electrode regarding linear working range, detection limit, lifetime and interferences. The advantages of this new electrode relative to those based on ionophores (such as crown ethers derivatives, [21][22][23][24][25][26] calixarene derivatives, [27][28][29] cryptand 22, 30 tetra-aza macrocycles [31][32][33] as well as other compounds [34][35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50][51][52][53] ) are discussed.…”
Section: Introductionmentioning
confidence: 99%
“…[22] All the functional groups of GO@NHC [23] were found to be present in the IR spectrum of GO@NHC ( Figure 1c) and the C=N stretching at 1,564 cm −1 along with the aromatic C-H vibrations in the region of 756-615 cm −1 confirm the formation of GO@NHC. [23] The presence of functional groups in the GO@NHC-Pd catalyst can be confirmed from Figure 1d. The peak at 1,129 cm −1 corresponds to the exact planar asymmetric stretching vibrations arising from the C-H bond of the palladium-coordinated N-heterocyclic carbene.…”
Section: Characterizationmentioning
confidence: 84%
“…Samples were stored at 4°C and analysis was performed within a month. Cold vapor atomic absorption spectrometry using a flow injection mercury system (FIMS-400) was used to determine urinary mercury (Tahir et al, 2012;Md. Noh et al, 1998).…”
Section: Methodsmentioning
confidence: 99%