1997
DOI: 10.1093/clinchem/43.7.1240
|View full text |Cite
|
Sign up to set email alerts
|

Five Osteocalcin Assays Compared: Tracer Specificity, Fragment Interference, and Calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…In addition, older assays were limited by their inability to distinguish the intact molecule from fragments. 17 Recently, a new assay specific for the intact protein has been developed. As a secondary aim of this study, we set out to establish the feasibility of using a modified assay specific for the intact OC protein to measure physiological concentrations present in healthy women.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, older assays were limited by their inability to distinguish the intact molecule from fragments. 17 Recently, a new assay specific for the intact protein has been developed. As a secondary aim of this study, we set out to establish the feasibility of using a modified assay specific for the intact OC protein to measure physiological concentrations present in healthy women.…”
Section: Introductionmentioning
confidence: 99%
“…It is localized in the membrane of osteoblasts and released into the circulation during activation of osteoblasts. 9 It has been reported that ligature-induced periodontitis reduced the serum levels of B-ALP. 10 Tartrate-resistant acid phosphatase 5b (TRAP-5b) is a specific and sensitive marker of osteoclasts.…”
mentioning
confidence: 99%
“…Bone alkaline phosphatase (B‐ALP) is a bone‐specific isoenzyme of ALP. It is localized in the membrane of osteoblasts and released into the circulation during activation of osteoblasts 9 . It has been reported that ligature‐induced periodontitis reduced the serum levels of B‐ALP 10 .…”
mentioning
confidence: 99%
“…The DBS matrix does not interfere with detection of osteocalcin as indicated by the linearity of dilution and spike and recovery results. In an earlier study, absence of dilutional linearity for serum samples (recovery values ranging from 200% to 700% for 1:8 dilution of serum) was found for several osteocalcin assays due to the presence of circulating osteocalcin fragments (Colford, Sailer, & Langman, ). In the current study, the variation in osteocalcin concentration between punches from duplicate blood spots run in wells on the same plate of around 8% was higher than that measured for plasma samples, but this result is reasonable given that this value encompasses well‐well variation in the osteocalcin concentration in addition to position‐based differences in analyte concentrations within a DBS.…”
Section: Discussionmentioning
confidence: 97%
“…Different assays vary in their ability to recognize the numerous fragments of osteocalcin, and specificity for one fragment vs another is, in many cases, not specified or evaluated by the manufacturer. Furthermore, even in cases where the specificity for a particular osteocalcin fragment or fragments has been reported by the manufacturer, this has been shown not to necessarily be accurate (Colford et al, ). Another limitation is that oral contraceptive use, hormone replacement therapy, diabetes mellitus, and body mass index <18 or >30 kg/m 2 can all affect (decrease) osteocalcin levels, but were not accounted for in our analyses.…”
Section: Discussionmentioning
confidence: 99%