2013
DOI: 10.1016/j.corsci.2013.07.019
|View full text |Cite
|
Sign up to set email alerts
|

Field studies of corrosion behaviour of copper alloys in natural seawater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
44
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(47 citation statements)
references
References 36 publications
1
44
0
Order By: Relevance
“…Since both treatments had similar initial copper ion release rates at section 16 and they both failed at the same time, this suggests that they had similar rates of release of copper ions during that 44-week period, even though bronze was expected to release copper ions at a lower rate due to the formation of an insoluble tin oxide layer (Drach et al 2013). Importantly, because of the similarities between the copper and bronze gradient tubes, either could be used interchangeably, and as an alternative to current polymer-based technologies (Braithwaite & McEvoy 2005;Braithwaite et al 2007;Guenther et al 2010).…”
Section: Discussionmentioning
confidence: 87%
“…Since both treatments had similar initial copper ion release rates at section 16 and they both failed at the same time, this suggests that they had similar rates of release of copper ions during that 44-week period, even though bronze was expected to release copper ions at a lower rate due to the formation of an insoluble tin oxide layer (Drach et al 2013). Importantly, because of the similarities between the copper and bronze gradient tubes, either could be used interchangeably, and as an alternative to current polymer-based technologies (Braithwaite & McEvoy 2005;Braithwaite et al 2007;Guenther et al 2010).…”
Section: Discussionmentioning
confidence: 87%
“…When the maximum stress is greater than the limit strength, the copper bending pipe will fail. For other failure modes such as cracks, their probability of occurrence can be ignored according to the existing studies [26,27]. …”
Section: Time-variant Reliability Modeling Methodsmentioning
confidence: 99%
“…Copper is a widely used material in large infrastructure applications (grounding, While studies concerning copper corrosion in atmospheric or aqueous environments are abundant in the literature [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26], the corrosion of copper or copper−based alloys in soils is scarce [26][27][28][29][30][31][32]. Despite this there is great importance in many industrial applications, as well as in archaeological studies of metal artifacts [30][31][32].…”