2019
DOI: 10.1016/j.xphs.2019.01.006
|View full text |Cite
|
Sign up to set email alerts
|

Factors Influencing Polysorbate's Sensitivity Against Enzymatic Hydrolysis and Oxidative Degradation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
86
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 65 publications
(92 citation statements)
references
References 30 publications
4
86
0
1
Order By: Relevance
“…PS80 was reported neither to have an effect on the thermostability of IgGs 37 nor to inhibit oxidation in IgG formulations. 19 Therefore, the inhibition of particle formation seen in formulations containing PS80 suggests interface-mediated aggregation as the predominant factor causing aggregation in dropped vials. Particle formation in formulations exposed to free-fall stress was suppressed in presence of PS80, and even at low PS80 concentrations (below CMC), solely a very small increase of micron-sized particles could be observed.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…PS80 was reported neither to have an effect on the thermostability of IgGs 37 nor to inhibit oxidation in IgG formulations. 19 Therefore, the inhibition of particle formation seen in formulations containing PS80 suggests interface-mediated aggregation as the predominant factor causing aggregation in dropped vials. Particle formation in formulations exposed to free-fall stress was suppressed in presence of PS80, and even at low PS80 concentrations (below CMC), solely a very small increase of micron-sized particles could be observed.…”
Section: Discussionmentioning
confidence: 99%
“…Functionality of both PS80 grades after long-term storage was not investigated but should be considered given the recently described differences in stability of MC-PS80 and ChP-PS80. 19 Further studies would also be necessary to evaluate if the "harsh" syringe pump stress conditions correlate with current Fill & Finish manufacturing conditions. Our study points out that it is important to monitor PS during drug product formulation development and stability testing of therapeutic proteins.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…164 In fact, only a few ppb of oxidative metals can be enough to degrade the protein as well as excipients (e.g., polysorbates) in the formulation that can be sensitive to this type of oxidative stress. 165…”
Section: Leachables and Extractablesmentioning
confidence: 99%