2001
DOI: 10.1016/s0925-4005(01)00855-3
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and characterization of electroosmotic micropumps

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

10
316
3
1

Year Published

2002
2002
2017
2017

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 382 publications
(330 citation statements)
references
References 29 publications
10
316
3
1
Order By: Relevance
“…This results in an uncorrected (α = 1) eo = (1.8 ± 0.1) 10 − 10 m 2 V −1 s −1 for 1 mM NaCl at pH = 5.7 ± 0.1. The Debye length for 1 mM NaCl is approximately 9.6 nm, resulting in a correction factor α = 0.9 (Ai et al 2010;Zeng et al 2001), and a corrected eo = (2.0 ± 0.1) 10 −10 m 2 V −1 s −1 . The zeta potential ζ, estimated from this electroosmotic mobility is as follows:…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…This results in an uncorrected (α = 1) eo = (1.8 ± 0.1) 10 − 10 m 2 V −1 s −1 for 1 mM NaCl at pH = 5.7 ± 0.1. The Debye length for 1 mM NaCl is approximately 9.6 nm, resulting in a correction factor α = 0.9 (Ai et al 2010;Zeng et al 2001), and a corrected eo = (2.0 ± 0.1) 10 −10 m 2 V −1 s −1 . The zeta potential ζ, estimated from this electroosmotic mobility is as follows:…”
Section: Resultsmentioning
confidence: 99%
“…The results from the limiting hydrodynamic pressure measurement can also be used to calculate µ eo , see (Zeng et al 2001): where Δp lim is the limiting hydrodynamic pressure and r the pore radius (0.2 µm), resulting in ζ = −1.9 ± 0.1 mV (corrected with α = 0.9), which is much smaller in magnitude than reported by others, e.g., −25 mV at pH = 6, for both pure polycarbonate and PVP-treated polycarbonate membranes (Kirby and Hasselbrink 2004;Lettmann et al 1999). Note that both ζ and eo should be calculated with the actual potential drop across the membrane, which we estimate to be about 75% of the actual applied potential, meaning that we have underestimated each by ~ 33%.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The majority of anions are the hydroxide ions, as our working fluid is the de-ionized water. Storage and handling of DI water often results in a slight decrease in the pH value and a slight increase in bulk conductivity [10]. This could be due to the presence of atmospheric carbon dioxide.…”
Section: B Experimental Setup and Measurementsmentioning
confidence: 99%