2020
DOI: 10.1109/tie.2019.2956373
|View full text |Cite
|
Sign up to set email alerts
|

Extending the Linear Modulation Range to Full Base Speed Independent of Load Power Factor for a Multilevel Inverter Fed IM Drive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…Thus, the magnitude of output voltage could be increased by 13.1% in the linear region. This improvement could be achieved without any topological change demanding more switches as that in [19], demonstrating the usefulness of the proposed scheme. Table 5 essentially gives a comparison with other 5-level inverters which attempts linear modulation range extension.…”
Section: Resultsmentioning
confidence: 77%
See 1 more Smart Citation
“…Thus, the magnitude of output voltage could be increased by 13.1% in the linear region. This improvement could be achieved without any topological change demanding more switches as that in [19], demonstrating the usefulness of the proposed scheme. Table 5 essentially gives a comparison with other 5-level inverters which attempts linear modulation range extension.…”
Section: Resultsmentioning
confidence: 77%
“…This uses only 21 switches as compared to that in [17], but extension achieved is only upto 0.945V dc . In [19], an OEWIM scheme capable of extending the linear modulation range to 0.955V dc is presented. However, this configuration requires a large number of switches (24 nos.)…”
Section: Introductionmentioning
confidence: 99%
“…In other words, the operation of an inverter in both the linear modulation and overmodulation modes requires two independent methods. Attractive overmodulation methods for two-level and multilevel inverters are proposed in literature [20][21][22][23][24] recently. Generally, these methods are performed through complex real-time calculation or lookup table implementation.…”
Section: Introductionmentioning
confidence: 99%
“…voltage DC bus where WIPS has been taken as the case study in [22]. However, regardless of different DC-link voltages, greater utilization of the power inverters is highly expected [23]. A larger speed without field weakening could allow the machine to minimize its weight and volume considerately, which can be beneficial for MEA applications [24], [25].…”
mentioning
confidence: 99%