2020
DOI: 10.1016/j.ijpharm.2020.119496
|View full text |Cite
|
Sign up to set email alerts
|

Exploring solid forms of oxytetracycline hydrochloride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 15 publications
0
5
0
1
Order By: Relevance
“…OxyCl solid forms were obtained as stated in our prior report [ 24 ]. OxyCl-II was produced by the slow evaporation of a saturated solution of commercial form (OxyCl-I) in isopropyl alcohol.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…OxyCl solid forms were obtained as stated in our prior report [ 24 ]. OxyCl-II was produced by the slow evaporation of a saturated solution of commercial form (OxyCl-I) in isopropyl alcohol.…”
Section: Methodsmentioning
confidence: 99%
“…Oxytetracycline hydrochloride (OxyCl) ( Figure 1 ) is a polymorphic tetracycline antibiotic of the broad-spectrum that is frequently used for treating respiratory tract infections, urethritis, severe acne, and also in the treatment of multidrug resistant malaria. Recent studies evidence that OxyCl polymorphs exhibited similar antimicrobial activity [ 24 ]. OxyCl is known to undergo several chemical reactions.…”
Section: Introductionmentioning
confidence: 99%
“…In general, different polymorphs show solubility differences typically smaller than 10 times due to relative differences in free energy. Some examples include the evaluation of solubility, in aqueous and buffer solutions, of several forms of furosemide [47], norfloxacin [48][49][50], albendazole [51], and oxytetracycline hydrochloride [52]. These studies demonstrate that the molecular arrangement of each polymorphic form and its degree of ionization has a considerable impact on drug solubility (Table 1).…”
Section: Solid Form Impact On Physicochemical and Biopharmaceutical P...mentioning
confidence: 99%
“…Bu sonuç, partikül kümeleri veya aglomeralarından kaynaklanabilecek, düzgün olmayan boyut ve şekle sahip yarık şekilli gözeneklerin (plakalar veya kenarlı partiküller) bir özelliğini göstermektedir [8] bölgelerden elde edilen klinoptilolitlerin pik verdiği açılarla benzerlik ve yakınlık göstermektedir [8,45]. Daha önce yapılan çalışmalarda TC'lerin XRD analizinde 2ϴ: 10,55-30,95˚ açısal aralıklarda pikler gösterdiği belirtilmiştir [46,47]. Karakteristik olarak doğal zeolit ile OTC-HCL adsorpsiyonundan sonra 2Ɵ: 9,96°-22,36°-26,71°-28,08°-30,26°-32,10° derecelerinde elde edilen zirveler bunu doğrulamaktadır.…”
Section: N2 Adsorpsiyon-desorpsiyon Analizi (N2 Adsorption-desorption...unclassified