2019
DOI: 10.1007/s10973-018-07998-5
|View full text |Cite
|
Sign up to set email alerts
|

Experimental thermodynamic analysis of a forced convection solar air heater using absorber plate with pin-fins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(14 citation statements)
references
References 16 publications
0
12
0
Order By: Relevance
“…10a highlighted that η th of SLSC was found to be higher than FPSC by 49.8%, 75%, 41% and 73%, respectively, for air mass flow rate of 0.006, 0.01, 0.015 and 0.02 kg s −1 . A solar collector with pin-fin type absorber plate demonstrated only 3-12% increase in the thermal efficiency of collector with respect to plain absorber plate [23]. It was also reported in a recent study that addition of only fins to arc shaped air heater led to maximum of 7% improvement in the thermal efficiency, but addition of fins along with baffles led to 28% increase in the thermal efficiency [21].…”
Section: Comparison Of Thermal Performance Of Fpsc With Slscmentioning
confidence: 54%
See 1 more Smart Citation
“…10a highlighted that η th of SLSC was found to be higher than FPSC by 49.8%, 75%, 41% and 73%, respectively, for air mass flow rate of 0.006, 0.01, 0.015 and 0.02 kg s −1 . A solar collector with pin-fin type absorber plate demonstrated only 3-12% increase in the thermal efficiency of collector with respect to plain absorber plate [23]. It was also reported in a recent study that addition of only fins to arc shaped air heater led to maximum of 7% improvement in the thermal efficiency, but addition of fins along with baffles led to 28% increase in the thermal efficiency [21].…”
Section: Comparison Of Thermal Performance Of Fpsc With Slscmentioning
confidence: 54%
“…The improved heat transfer in the collector with fin/turbulators is attributed to the promotion of turbulence, improved mixing and breaking of thermal boundary layer found adjacent to the absorber plate [22]. Sivakumar et al [23] found 17 °C higher outlet air temperature, 12% higher thermal efficiency along with 60% increase in pressure drop in pin-fin collector as compared to conventional FPSC. Manoram et al [24] reported the significant effect of pitchto-diameter ratio and the number of dimples on the thermal efficiency and friction factor of solar water heating system.…”
Section: Introductionmentioning
confidence: 99%
“…They concluded that the highest efficiency was 62.5% for double pass baffle and 55% for singlepass baffle for the mass flow rate of 0.032 kg/s. In a further investigation, Sivakumar et al 18 experimentally investigated the thermodynamic performance of forced convection solar air heater using a pin-fin absorber plate. In their study, it has been observed that the pin-fin absorber has improved the system's performance with the least amount of pressure drop across the solar air heater than the smooth SAH.…”
Section: Introductionmentioning
confidence: 99%
“…14 In another work, the energy and exergy efficiency of a SACusing pin-fin absorber were improved by 3-12% and 2-11%, respectively compared to flat absorber. 15…”
Section: Introductionmentioning
confidence: 99%