2010
DOI: 10.1088/1367-2630/12/8/083015
|View full text |Cite
|
Sign up to set email alerts
|

EUV Hartmann sensor for wavefront measurements at the Free-electron LASer in Hamburg

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
28
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 14 publications
1
28
0
2
Order By: Relevance
“…From the measured spot pattern the employed evaluation software [144] computes the wavefront in terms of a linear superposition of the Zernike polynomials. Under the assumption of full coherence, beam parameters such as waist diameter, divergence or astigmatic waist difference are derived [145]. In the following these properties are compared to the results from the precedent caustic scan.…”
Section: Results From Wavefront Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…From the measured spot pattern the employed evaluation software [144] computes the wavefront in terms of a linear superposition of the Zernike polynomials. Under the assumption of full coherence, beam parameters such as waist diameter, divergence or astigmatic waist difference are derived [145]. In the following these properties are compared to the results from the precedent caustic scan.…”
Section: Results From Wavefront Measurementmentioning
confidence: 99%
“…On the other hand, the evaluation of PMMA imprints can also result in underestimated beam sizes [145]. In any case, the global degree of coherence is strongly dependent on the derived beam diameter, as relations (3.27) and (3.36) reveal.…”
Section: Coherence Properties Of the Flash Beammentioning
confidence: 98%
“…In total, 13 consecutive HH wavefronts were recorded in the same conditions for HHG and compared to estimate the stability of the wavefront. The HH wavefronts were reconstructed using the software MrBeam [24]. Prior to wavefront reconstruction, a dark image was subtracted and hot pixels were removed for each measurement.…”
Section: Wavefront Measurementmentioning
confidence: 99%
“…For direct measurement of the XUV intensity profile, the XUV camera is placed directly after the filters without spectrometer. For wavefront measurement, the XUV camera is replaced by a XUV wavefront sensor with alignment for tip/tilt and the vertical/horizontal axis [24,25] and a 300 nm-thick Al filter without supporting mesh is used. …”
Section: Introductionmentioning
confidence: 99%
“…Im Rahmen der vorliegenden Arbeit wurden zwei Wellenfrontsensoren für den Einsatz an FLASH aufgebaut und dort sowie an LCLS verwendet. Mit den Sensoren wurden die Strahlpropagationsparameter der Beamlines bestimmt und die Fokussierspiegel justiert [15,16]. Trotz fehlerarmer und gut justierter Optiken kann der Wärmeeintrag in die Spiegel zur Herausbildung transienter Aberrationen der Wellenfront führen.…”
unclassified