1976
DOI: 10.1115/1.3450581
|View full text |Cite
|
Sign up to set email alerts
|

Error in Temperature Measurements Due to Conduction Along the Sensor Leads

Abstract: When a sensor is embedded in a solid body to measure its internal temperature, any conduction to, or from, its sensing element may cause the indicated temperature to be different from the true temperature. This paper describes an analysis of the error caused by conduction when there is an arbitrary temperature distribution in thebbody along the sensor. The sensor is modeled as a cylindrical fin and the appropriate conduction equation is solved. The solution gives a correction for the error which depends on suc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

1977
1977
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(10 citation statements)
references
References 0 publications
0
9
0
1
Order By: Relevance
“…Generally, we can conclude from these results that the effect of the stripped insulation of any length on the temperature measurement is negligible or, more accurately the experimental error for a typical system is higher than the effect of the stripped insulation [6], see Figure 2(ab). Besides, the temperature difference between the environment and the working range of the peltier surface 4 o C-35 o C is not high enough to have a strong effect on the temperature measurement, see Figure 13.…”
Section: Resultsmentioning
confidence: 88%
See 3 more Smart Citations
“…Generally, we can conclude from these results that the effect of the stripped insulation of any length on the temperature measurement is negligible or, more accurately the experimental error for a typical system is higher than the effect of the stripped insulation [6], see Figure 2(ab). Besides, the temperature difference between the environment and the working range of the peltier surface 4 o C-35 o C is not high enough to have a strong effect on the temperature measurement, see Figure 13.…”
Section: Resultsmentioning
confidence: 88%
“…Fin analysis considers heat transfer by conduction occurring along the thermocouple wire due to its high thermal conductivity in comparison with the surrounding insulation, as such it assumes that there is no radial temperature gradient across the metal wire [6], see Table 1.…”
Section: Thermocouple Wire Lengthmentioning
confidence: 99%
See 2 more Smart Citations
“…Singh et al [46] have given a more detailed solution including the end-effects, which reduces to Eq. (10) when endeffects are insignificant.…”
Section: A Strategy To Minimise the Effect Of Environment On Thermocomentioning
confidence: 99%