2018
DOI: 10.1016/j.epsr.2018.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced controller for grid-connected modular multilevel converters in distorted utility grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 48 publications
0
9
0
Order By: Relevance
“…The platform for this study is built with the TMS320F28379D microcontroller from Texas Instruments [54] and the PLECS RT Box1 (Plexim) HIL boards with several analogues and digital input/outputs [55] (see Figure 11). The file with the C-code was created and uploaded into both targets [46], and the voltages and currents measurements are recorded in the host PC in order to monitor them as described in Figure 11. Tables 2 and 3 present the power parameters for the grid side and the control subsystem parameters, respectively.…”
Section: Controller Hardware-in-the-loop Simulation For the Grid-sidementioning
confidence: 99%
See 2 more Smart Citations
“…The platform for this study is built with the TMS320F28379D microcontroller from Texas Instruments [54] and the PLECS RT Box1 (Plexim) HIL boards with several analogues and digital input/outputs [55] (see Figure 11). The file with the C-code was created and uploaded into both targets [46], and the voltages and currents measurements are recorded in the host PC in order to monitor them as described in Figure 11. Tables 2 and 3 present the power parameters for the grid side and the control subsystem parameters, respectively.…”
Section: Controller Hardware-in-the-loop Simulation For the Grid-sidementioning
confidence: 99%
“…The GSC is able to regulate the DC voltage in order to generate the reference of active power 188 , by using a PI regulator [46] and also to regulate the injected reactive power into the utility 189 grid. The latter is achieved by regulating properly the P-N SCs of the grid currents to deal with the 190 grid voltage disturbance conditions and the power oscillations furnished by the RSC to the DC-link.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The increase of the penetration of renewable agents in the energy mix [1], together with the necessity to maintain the stability of the electric power systems make the new grid codes more restrictive nowadays for grid-connected photovoltaic (PV) systems and other renewable agents [2][3][4][5]. For example, these systems must remain connected under certain conditions so as to improve the voltage profile of the utility grid when there are voltage sags [6][7][8]. In addition, the amplitude of the three-phase inverter currents needs to be limited to its nominal value in order to avoid its automatic disconnection from the utility grid avoiding the inverter failure.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the amplitude of the three-phase inverter currents needs to be limited to its nominal value in order to avoid its automatic disconnection from the utility grid avoiding the inverter failure. The two conditions mentioned above are known as Low-Voltage-Ride-Through (LVRT) capability [8].…”