2011
DOI: 10.1002/ceat.201000298
|View full text |Cite
|
Sign up to set email alerts
|

Electrokinetic Mobilities Characterization and Rapid Detection of Microorganisms in Glass Microchannels

Abstract: Microscale electrokinetic techniques have great potential for the separation and sorting of microorganisms, and could solve the need for rapid and early detection of pathogens in medical diagnostics and food safety applications. Presented here is the application of micro particle image velocimetry for the characterization of electrokinetic transport of three types of microorganisms: Escherichia coli, Ankistrodesmus spiralis, and Saccharomyces cerevisiae. The electrokinetic behavior of these microorganisms was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…Alignment and concentration have been demonstrated for metallic objects like nano wires [6] and gold nanoparticles [7] as well as for DNA molecules and DNA nanostructures (''DNA origami'') [8][9][10]. Both viruses [11,12] and proteins have been locally enriched [13][14][15]. In most cases the optimal experimental conditions appear to have been found empirically.…”
Section: Introductionmentioning
confidence: 94%
“…Alignment and concentration have been demonstrated for metallic objects like nano wires [6] and gold nanoparticles [7] as well as for DNA molecules and DNA nanostructures (''DNA origami'') [8][9][10]. Both viruses [11,12] and proteins have been locally enriched [13][14][15]. In most cases the optimal experimental conditions appear to have been found empirically.…”
Section: Introductionmentioning
confidence: 94%
“…This point can be also extrapolated to microchip‐CE development that it is also expected to keep technologically growing as well as its applications in food analysis. Despite the predominant use of electrochemical detection with microchip CE, novel applications of microchip CE devices and fluorecence detection can be also foreseen in the nondistant future in food analysis . The use of MS is becoming a more frequent alternative detection in CE and it is expected to be also more generally used in food science.…”
Section: Foodomics and Other Future Trends Of Ce In Food Analysismentioning
confidence: 99%
“…. These flat channels are commonly used for PIV measurements . Figure shows the total displacement obtained when AC signals starting at ±800 V were applied at the frequencies of 1 Hz (Fig.…”
Section: Resultsmentioning
confidence: 99%