We have trapped single protein molecules of R-phycoerythrin in an aqueous solution by an alternating electric field. A radio frequency voltage is applied to sharp nanoelectrodes and hence produces a strong electric field gradient. The resulting dielectrophoretic forces attract freely diffusing protein molecules. Trapping takes place at the electrode tips. Switching off the field immediately releases the molecules. The electric field distribution is computed, and from this the dielectrophoretic response of the molecules is calculated using a standard polarization model. The resulting forces are compared to the impact of Brownian motion. Finally, we discuss the experimental observations on the basis of the model calculations.
BackgroundNucleic acid amplification is the most sensitive and specific method to detect Plasmodium falciparum. However the polymerase chain reaction remains laboratory-based and has to be conducted by trained personnel. Furthermore, the power dependency for the thermocycling process and the costly equipment necessary for the read-out are difficult to cover in resource-limited settings. This study aims to develop and evaluate a combination of isothermal nucleic acid amplification and simple lateral flow dipstick detection of the malaria parasite for point-of-care testing.MethodsA specific fragment of the 18S rRNA gene of P. falciparum was amplified in 10 min at a constant 38°C using the isothermal recombinase polymerase amplification (RPA) method. With a unique probe system added to the reaction solution, the amplification product can be visualized on a simple lateral flow strip without further labelling. The combination of these methods was tested for sensitivity and specificity with various Plasmodium and other protozoa/bacterial strains, as well as with human DNA. Additional investigations were conducted to analyse the temperature optimum, reaction speed and robustness of this assay.ResultsThe lateral flow RPA (LF-RPA) assay exhibited a high sensitivity and specificity. Experiments confirmed a detection limit as low as 100 fg of genomic P. falciparum DNA, corresponding to a sensitivity of approximately four parasites per reaction. All investigated P. falciparum strains (n = 77) were positively tested while all of the total 11 non-Plasmodium samples, showed a negative test result. The enzymatic reaction can be conducted under a broad range of conditions from 30-45°C with high inhibitory concentration of known PCR inhibitors. A time to result of 15 min from start of the reaction to read-out was determined.ConclusionsCombining the isothermal RPA and the lateral flow detection is an approach to improve molecular diagnostic for P. falciparum in resource-limited settings. The system requires none or only little instrumentation for the nucleic acid amplification reaction and the read-out is possible with the naked eye. Showing the same sensitivity and specificity as comparable diagnostic methods but simultaneously increasing reaction speed and dramatically reducing assay requirements, the method has potential to become a true point-of-care test for the malaria parasite.
A bienzyme substrate-recycling biosensor in a flow injection analysis system is described for the sensitive measurement of alkaline phosphatase (ALP) and applied to the fast readout of a competitive immunoassay for the widely used pesticide 2,4-dichlorophenoxyacetic acid (2,4-D). The phenol-indicating biosensor consists of a Clark-type electrode covered by a membrane with coentrapped tyrosinase and quinoprotein glucose dehydrogenase. ALP dephosphorylates phenyl phosphate to phenol (K(m) = 36 microM) outside the flow system. Phenol is oxidized in the sensor membrane by the oxygen-consuming tyrosinase via catechol to o-quinone. The quinone is reconverted to catechol by glucose dehydrogenase. This substrate cycling results in a 350-fold amplified sensor response to phenol. The oxygen consumption of the enzyme couple in the presence of phenol is monitored as a decrease in current. A total of 3.2 fM ALP (320 zmol/ 100 microL) has been detected after a 57.5 min incubation with phenyl phosphate. All involved reagents are stable over the time of measurement. The sensor does not produce any measurable blank signals. The immunoassay detects 0.1 microgram/L 2,4-D, the maximum concentration for pesticides allowed in drinking water by European Community regulations. The applicability of this biosensor for fast immunoassay readout is demonstrated by a 2 min incubation. By comparison, a standard photometric method (p-nitrophenyl phosphate) requires overnight incubation.
We report on the development of an on-chip RPA (recombinase polymerase amplification) with simultaneous multiplex isothermal amplification and detection on a solid surface. The isothermal RPA was applied to amplify specific target sequences from the pathogens Neisseria gonorrhoeae, Salmonella enterica and methicillin-resistant Staphylococcus aureus (MRSA) using genomic DNA. Additionally, a positive plasmid control was established as an internal control. The four targets were amplified simultaneously in a quadruplex reaction. The amplicon is labeled during on-chip RPA by reverse oligonucleotide primers coupled to a fluorophore. Both amplification and spatially resolved signal generation take place on immobilized forward primers bount to expoxy-silanized glass surfaces in a pump-driven hybridization chamber. The combination of microarray technology and sensitive isothermal nucleic acid amplification at 38 °C allows for a multiparameter analysis on a rather small area. The on-chip RPA was characterized in terms of reaction time, sensitivity and inhibitory conditions. A successful enzymatic reaction is completed in <20 min and results in detection limits of 10 colony-forming units for methicillin-resistant Staphylococcus aureus and Salmonella enterica and 100 colony-forming units for Neisseria gonorrhoeae. The results show this method to be useful with respect to point-of-care testing and to enable simplified and miniaturized nucleic acid-based diagnostics.FigureThe combination of multiplex isothermal nucleic acid amplification with RPA and spatially-resolved signal generation on specific immobilized oligonucleotidesElectronic supplementary materialThe online version of this article (doi:10.1007/s00604-014-1198-5) contains supplementary material, which is available to authorized users.
A novel innovative approach towards a marketable lab-on-chip system for point-of-care in vitro diagnostics is reported. In a consortium of seven Fraunhofer Institutes a lab-on-chip system called "Fraunhofer ivD-platform" has been established which opens up the possibility for an on-site analysis at low costs. The system features a high degree of modularity and integration. Modularity allows the adaption of common and established assay types of various formats. Integration lets the system move from the laboratory to the point-of-need. By making use of the microarray format the lab-on-chip system also addresses new trends in biomedicine. Research topics such as personalized medicine or companion diagnostics show that multiparameter analyses are an added value for diagnostics, therapy as well as therapy control. These goals are addressed with a low-cost and self-contained cartridge, since reagents, microfluidic actuators and various sensors are integrated within the cartridge. In combination with a fully automated instrumentation (read-out and processing unit) a diagnostic assay can be performed in about 15 min. Via a user-friendly interface the read-out unit itself performs the assay protocol, data acquisition and data analysis. So far, example assays for nucleic acids (detection of different pathogens) and protein markers (such as CRP and PSA) have been established using an electrochemical read-out based on redoxcycling or an optical read-out based on total internal reflectance fluorescence (TIRF). It could be shown that the assay performance within the cartridge is similar to that found for the same assay in a microtiter plate. Furthermore, recent developments are the integration of sample preparation and polymerase chain reaction (PCR) on-chip. Hence, the instrument is capable of providing heating-and-cooling cycles necessary for DNA-amplification. In addition to scientific aspects also the production of such a lab-on-chip system was part of the development since this heavily affects the success of a later market launch. In summary, the Fraunhofer ivD-platform covers the whole value chain ranging from microfluidics, material and polymer sciences, assay and sensor development to the production and assembly design. In this consortium the gap between diagnostic needs and available technologies can be closed.
The molecular dynamics of linear poly(N-isopropylacrylamide) (pNIPAM) in aqueous media at temperatures below and above the lower critical solution temperature (LCST) are investigated using broadband dielectric relaxation spectroscopy in a frequency range from 10(-1) to 10(11) Hz. Below the LCST, two relaxation processes are observed in the megahertz and gigahertz region assigned to the reorientation of dipoles of the solvated polymer segments (p-process) and water molecules (w-process), respectively. Both relaxation processes are analyzed using the Havriliak-Negami (HN) function, taking special attention to the w-process. Above the LCST, the dielectric spectra of the pNIPAM solutions resemble that of pure water, showing only the high frequency relaxation process of the water molecules with a more or less Debye-type behavior. The non-Debye behavior of the w-process below the LCST is mainly induced by the interactions between water and pNIPAM chains via hydrogen bonding. The relaxation time and strength of the w-process is studied with dependence on the concentration, temperature, and the polymer chain length (molecular weight). The information obtained is useful for a deeper understanding of the dehydration behavior at the phase transition. The suggestion of dehydration of the pNIPAM chains at the LCST is confirmed by calculating a dehydration number.
A biosensor for l-adenosine employing high-affinity RNA as binder is reported. Real-time measurement is obtained using total internal reflection fluorescence in a fiber-optic format. High-affinity RNA was attached to the core of a multimode fiber via an avidin−biotin bridge. The sensor measures binding of FITC-labeled l-adenosine. The interaction was fully characterized by the determination of association and dissociation rates: k D = 0.0119 s-1; k A = 2200 M-1 s-1. Competitive inhibition with l-adenosine enables this device to detect l-adenosine in the submicromolar range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.