1979
DOI: 10.1080/00032717908067911
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Oxidation of Derivatives of Dibenzodiazepin. Dibenzothiazepin and Dibenzoxazepin

Abstract: ASSTRACT Clozapin exhib its two anodic waves at> 1 M H"SO.,b ut at lower acidities only the first two-electron 2 4 •' wave remains.Cyc1ic voltommetry shows an ECE mechanism.-4 Reversib i1ity cecreases at>1C M concentrations,due to formation of an adsorptioo film.In nonaqueous solveib ts two irréversib le one-electron waves appear.Clothiopin and lox opin are more difficultly oxidized and can b e measured in the présence of clozapin. 1217

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
17
0

Year Published

1985
1985
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 6 publications
1
17
0
Order By: Relevance
“…12,13 This established sensing modality is furthermore well suited for miniaturization, required for small-volume pointof-care solutions. 14, 15 We have recently presented the application of the catechol-modified chitosan redox cycling system to amplify and detect the electrochemical clozapine signal in undiluted human serum.…”
Section: Introductionmentioning
confidence: 99%
“…12,13 This established sensing modality is furthermore well suited for miniaturization, required for small-volume pointof-care solutions. 14, 15 We have recently presented the application of the catechol-modified chitosan redox cycling system to amplify and detect the electrochemical clozapine signal in undiluted human serum.…”
Section: Introductionmentioning
confidence: 99%
“…The LOD and LOQ were estimated as LOD = 3 S B /b and LOQ = 10 S B /b [53], where S B is the standard deviation of the blank and b is the slope of the calibration curve. The estimated values of LOD and LOQ ( Table 2) show an improvement in sensitivity of the proposed SWAdCS voltammetric procedure for quantification of clozapine in bulk and tablets compared to that of the reported [39][40][41][42][43][44] electrochemical methods (LOQ = 1 × 10 −6 to 8 × 10 −9 M).…”
Section: Validation Of the Proposed Analysis Proceduresmentioning
confidence: 97%
“…In addition, several electrochemical methods have been reported in the literature for determination of clozapine in bulk form and tablets including dc-and differential-pulse polarography [39], differential-pulse adsorptive cathodic stripping voltammetry at a hanging mercury drop electrode [40], linear sweep anodic stripping voltammetry at an activated glassy carbon electrode [41], anodic voltammetry at rotating platinum, glassy carbon disk and stationary carbon paste electrodes [42] and a wax-impregnated graphite electrode [43]. The behavior of clozapine was studied by adsorptive anodic voltammetry in order to carry out its direct determination in biological fluids [44].…”
Section: Introductionmentioning
confidence: 99%
“…The electrochemical behavior of CLZ was evaluated, and several polarographic and voltammetric methods have been reported for the electrochemical study of CLZ in literature [13][14][15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…The ISS-CILE also showed an improvement in sensitivity compared to the CILE which implies that the redox reaction of CLZ molecules become more facile on the ISS-CILE (Figure 1c (TX-100), 1d (SDS)). Moreover, the ECE mechanism in which the initial oxidation product is chemically transformed to a compound which is more readily oxidized than the parent compound and is the accepted mechanism for electrochemical behavior of CLZ is only detectable at CILE and ISS-CILE from the first scan [49].…”
mentioning