2016
DOI: 10.1016/j.snb.2016.07.064
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical impedance spectroscopy with interdigitated electrodes at the end of hypodermic needle for depth profiling of biotissues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
34
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 40 publications
(35 citation statements)
references
References 20 publications
1
34
0
Order By: Relevance
“…A dielectric property is, therefore, associated with biological tissue wherein the relative permittivity reduces with increasing frequency [10]. Previous studies reported the monopolar, bipolar, or quadripolar microelectrode integrated needle using impedance measurement for the tissue characterization [3,[11][12][13][14][15][16]. The microelectrode based impedance measurement showed the possibility of tissue discrimination with needle guidance [3,13,14].…”
Section: Introductionmentioning
confidence: 99%
“…A dielectric property is, therefore, associated with biological tissue wherein the relative permittivity reduces with increasing frequency [10]. Previous studies reported the monopolar, bipolar, or quadripolar microelectrode integrated needle using impedance measurement for the tissue characterization [3,[11][12][13][14][15][16]. The microelectrode based impedance measurement showed the possibility of tissue discrimination with needle guidance [3,13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Based on these advantages and previous studies on the electrical impedance measurement for tissue discrimination, biopsy needles with electrical impedance spectroscopy (EIS) capability to investigate the tissue properties near the needle tip have been developed by several researchers to overcome the above mentioned limitations of conventional image-guided biopsy process 14 17 as shown in Fig. 1(c) .…”
Section: Introductionmentioning
confidence: 99%
“…reported the EIS needle with interdigitated electrodes for impedance measurement based on conventional semiconductor fabrication technique. They show the miniaturized interdigitated electrodes with width less than 400 μm which is applicable to needle with diameter of 700 μm (22-gauges) 17 . However, only 2-electrode measurement technique is possible in those configuration.…”
Section: Introductionmentioning
confidence: 99%
“…A micro electrical impedance spectroscopy-on-a-needle (μEoN), which is a needle combined with an electrical impedance sensor on the needle tip, was introduced to locate the boundaries between dissimilar tissues [26]. However, the sensing electrodes, completely covered by the passivation layer, created unwanted signals from the connection lines that seriously influenced the sensor output.…”
Section: Introductionmentioning
confidence: 99%