2019
DOI: 10.3390/app9194049
|View full text |Cite
|
Sign up to set email alerts
|

Electrical Characterization of Pork Tissue Measured by a Monopolar Injection Needle and Discrete Fourier Transform based Impedance Measurement

Abstract: Ultrasonography or fluoroscopy-guided needle injection has been used for intra-articular injection therapy against adhesive capsulitis and joint diseases. To improve the image-guided intra-articular injection therapy, electrical impedance measurement based positioning of the needle tip in the target tissue can be applied. The feasibility of the discrimination for the tissue layer at which the disposable monopolar injection needle tip position was investigated using the discrete Fourier transform (DFT)-based im… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…A parylene-coating test was conducted to check the impedance of the MNE before and after the parylene coating. We used 0.9% NaCl for the test because it has the same pH and conductivity levels as the human extracellular fluids [ 29 , 30 ]. The MNEs were immersed in a 0.9% NaCl solution, and the other side was connected to the impedance-measurement system CompactStat potentiostat from IVIUM Technologies (Eindhoven, The Netherlands).…”
Section: Methodsmentioning
confidence: 99%
“…A parylene-coating test was conducted to check the impedance of the MNE before and after the parylene coating. We used 0.9% NaCl for the test because it has the same pH and conductivity levels as the human extracellular fluids [ 29 , 30 ]. The MNEs were immersed in a 0.9% NaCl solution, and the other side was connected to the impedance-measurement system CompactStat potentiostat from IVIUM Technologies (Eindhoven, The Netherlands).…”
Section: Methodsmentioning
confidence: 99%
“…On the PC the data is averaged to get the best data. The time required is around 600 ms. (d) Calculation the value of 'mag (dB)' using Equation (15) and the value of 'θ (degree)' using Equation (16). Calculation the value of complex impedance magnitude, real part and imaginary part of complex impedance using Equation (17).…”
Section: Prototype Of the Bis Instrumentation Systemmentioning
confidence: 99%
“…The α-dispersion (10 Hz to 10 kHz) is related to the phenomena of ionic diffusion of the cell membrane and the counterion effects, the β-dispersion (10 kHz to 100 MHz) is related to the polarization phenomenon of cell membranes, and the γ-dispersion (in GHz order) is related to the polarization of water molecules [3]. Properties of electrical impedance have been reported to understand the nature and behavior of cell [4][5][6][7][8], bacteria detection and identification [9,10], identification of beverages and food ingredients [11][12][13][14][15][16], and so on. In the medical field, BIS is used to characterizations of serum and blood [17][18][19], identification of body composition and disease [20][21][22], and to assist the process of diagnosis and functional electrical stimulation of the body [23][24][25].…”
Section: Introductionmentioning
confidence: 99%
“…A monopolar needle was used to simultaneously measure the impedance and administer the drug. Electrical impedance monitoring revealed major differences between the dermis, hypodermis, and muscle tissue [23,24].…”
Section: Introductionmentioning
confidence: 99%