Electrical characterization intercomparison of high‐efficiency c‐Si modules within Asian and European laboratories

Abstract: This work presents the results of a high-efficiency (HE) photovoltaic (PV) module roundrobin intercomparison between five Asian and European ISO/IEC 17025 accredited laboratories and one industrial laboratory based in Europe. The scope of the round-robin was to examine the measurements comparability for this PV technology with respect to ISO/IEC 17025 laboratory conformity assessment and also to examine the accuracy of step-like methods towards transient errors against already validated methods. The devices un… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 20 publications
0
13
0
Order By: Relevance
“…As mentioned above, the methodology used to assess the participants' results against the reference value was based on the standard ISO/IEC 17043 34 and on previous experience. [21][22][23]25 Figure 3) at the end of the RR, when the DUT returned there, and before any further preconditioning to take it back to a stabilised state. The additional stabilisation brought this DUT to a P max value −10.9% (ES in Figure 3) smaller than the RMPT value, showing a significant change in the electrical performance of the device.…”
Section: Methodology For Results Assessmentmentioning
confidence: 99%
See 4 more Smart Citations
“…As mentioned above, the methodology used to assess the participants' results against the reference value was based on the standard ISO/IEC 17043 34 and on previous experience. [21][22][23]25 Figure 3) at the end of the RR, when the DUT returned there, and before any further preconditioning to take it back to a stabilised state. The additional stabilisation brought this DUT to a P max value −10.9% (ES in Figure 3) smaller than the RMPT value, showing a significant change in the electrical performance of the device.…”
Section: Methodology For Results Assessmentmentioning
confidence: 99%
“…The RR was organised within the CHEETAH project 33 as a PT for 13 participating laboratories, also building on a failure analysis of the SOPHIA project's RR and on prior experience in interlaboratory comparisons. [21][22][23]25 The reference measurements were independently provided by ESTI, which calibrated all devices at the beginning of the PT (see Section 2.4). The devices were again shipped to ESTI at the end of the RR PT for a final verification and calibration.…”
Section: Organisation and Protocol Of The Rr Ptmentioning
confidence: 99%
See 3 more Smart Citations