1995
DOI: 10.1049/ip-gtd:19951728
|View full text |Cite
|
Sign up to set email alerts
|

Efficient methods for identifying weak nodes in electrical power networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2000
2000
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(19 citation statements)
references
References 0 publications
0
19
0
Order By: Relevance
“…The weakest bus may be identified through a static analysis, even though the final consequence is the loss of dynamic stability [16]. The weakest bus indicates that the bus with the most sensitive voltage and relatively heavy load [17], which is also the starting point of system voltage collapse.…”
Section: A.pqv Characteristics At Load Busmentioning
confidence: 99%
See 2 more Smart Citations
“…The weakest bus may be identified through a static analysis, even though the final consequence is the loss of dynamic stability [16]. The weakest bus indicates that the bus with the most sensitive voltage and relatively heavy load [17], which is also the starting point of system voltage collapse.…”
Section: A.pqv Characteristics At Load Busmentioning
confidence: 99%
“…From [17], [19]- [20], it can be concluded that the weak buses rankings using the different methods for the normal condition according to the different approaches are similar. The profiles of the system voltage under the specific contingencies are the major concern of this paper.…”
Section: Identification Of the Weakest Busesmentioning
confidence: 99%
See 1 more Smart Citation
“…They are based on multiple load flow solution such as the Voltage Instability Proximity Index (VIPI) and Voltage Collapse Proximity Indicator (VCPI). Evaluation techniques based on load flow full of or reduced Jacobian analysis such as singular value decomposition, eigenvalue calculation, sensitivity factors and modal analysis are time consuming for a large power system [6][7][8]. More robust and efficient index for determining the set of low-voltage solutions closest to the operatable solution is also used.…”
Section: Introductionmentioning
confidence: 99%
“…They are based on multiple load flow solutions and give only global picture [5,6]. The transmission proximity index that specifies the weakest transmission part of the system based on voltage phasor approach necessitate the scanning of the whole power system structure for several time which the time consuming approach [7].…”
Section: Introductionmentioning