2011 Loughborough Antennas &Amp; Propagation Conference 2011
DOI: 10.1109/lapc.2011.6114075
|View full text |Cite
|
Sign up to set email alerts
|

Effects of the metallic spectacles with braces added on Specific Absorption Rate (SAR) exposed to frontal radiation sources

Abstract: The investigation on the changes of Specific Absorption Rate (SAR) inside the head due to metallic straight pin with simple braces added is presented in this paper. The finite integration in time domain (FIT) computer simulation technique was used in this investigation. The head is irradiated by dipole sources in front of the Specific Anthropomorphic Mannequin (SAM) face. Parametric studies show that 1 gram SAR at 900MHz is slightly reduced. However at 1800MHz, it decreased if pin lengths were varied longer th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…Table 2 shows the parameters of the head simulating liquid (HSL) used for both of the GSM frequency ranges used. The results for all simulations were normalized to 1 Watt accepted power, and the worst case scenario was assumed to be the case in which the mobile phone's antenna required more power when operated at a long distance from base stations [31]. This SAM phantom head model was a good choice for observing radiation patterns and for fast calculations, but its accuracy was suboptimal.…”
Section: Head Modelsmentioning
confidence: 99%
“…Table 2 shows the parameters of the head simulating liquid (HSL) used for both of the GSM frequency ranges used. The results for all simulations were normalized to 1 Watt accepted power, and the worst case scenario was assumed to be the case in which the mobile phone's antenna required more power when operated at a long distance from base stations [31]. This SAM phantom head model was a good choice for observing radiation patterns and for fast calculations, but its accuracy was suboptimal.…”
Section: Head Modelsmentioning
confidence: 99%
“…Specific absorption is defined as the quotient of the incremental energy (dE) absorbed by an incremental mass (dm) contained in a volume (dV) of a given density (ρ). However, specific absorption rate (SAR) is defined as the rate of energy (dE) absorbed or dissipated in an incremental mass (dm) contained in an incremental volume (dV) of a given density (ρ) [1]- [3], [5]- [10], [15]- [31]. Mathematically, SAR can be expressed in watt per kilogram (W/kg) as However, the SAR for specifying the radiofrequency absorption by tissue can be calculated at any location in the tissue from the electric field (E) as shown below:…”
Section: Introductionmentioning
confidence: 99%