Effects of microcystins-containing cyanobacteria from a temperate ecosystem on human lymphocytes culture and their potential for adverse human health effects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 51 publications
1
14
0
Order By: Relevance
“…In previous studies, the presence of CYN was revealed in 17 lakes in Poland. The concentrations of the toxin in seston ranged from trace amounts to 3.0 µg dm -3 (Kokociński et al 2009(Kokociński et al , 2013 and were comparable to the concentrations determined in German water bodies during the bloom of Aph. flos-aquae (Preußel et al 2006, Rücker et al 2007).…”
Section: Cyanotoxins In Polish Water Bodiessupporting
confidence: 77%
“…In previous studies, the presence of CYN was revealed in 17 lakes in Poland. The concentrations of the toxin in seston ranged from trace amounts to 3.0 µg dm -3 (Kokociński et al 2009(Kokociński et al , 2013 and were comparable to the concentrations determined in German water bodies during the bloom of Aph. flos-aquae (Preußel et al 2006, Rücker et al 2007).…”
Section: Cyanotoxins In Polish Water Bodiessupporting
confidence: 77%
“…The Antx-a concentration was determined by HPLC using a diode array detection (DAD) detector (model SPD-M20A Prominence HPLC, Shimadzu, USA) according to the method described by Mankiewicz et al [22]. Analysis of the pure extract revealed the presence of Antx-a at a concentration of 2.2 mg/l.…”
Section: Pure Extract Preparations and Analysis Of Anatoxin-amentioning
confidence: 99%
“…Cyanobacterial extracts were prepared as in our previous studies (Mankiewicz-Boczek et al, 2011); specifically, 1000 mg of freezedried cyanobacterial material for each sample were dissolved in 60 ml of 75% methanol and sonicated on ice for 10 min to release toxic compounds from cyanobacterial cells. Afterwards, samples were centrifuged for 10 min at 10,000× g at 4 • C. At the end, the supernatants were filtered using Whatman solid-state PTFE filters.…”
Section: Crude Cyanobacterial Extractsmentioning
confidence: 99%
“…Microcystins in crude and purified cyanobacterial extracts were determined as described by Mankiewicz-Boczek et al (2011). Briefly, analysis was performed by HPLC with a diode array detection (DAD) detector (model 1100, Hewlett Packard) according to the method principle of Meriluoto and Codd (2005).…”
Section: Analysis Of Microcystinsmentioning
confidence: 99%