2006
DOI: 10.1016/j.ijrefrig.2005.12.011
|View full text |Cite
|
Sign up to set email alerts
|

Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
43
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 83 publications
(51 citation statements)
references
References 6 publications
3
43
0
Order By: Relevance
“…CFD simulation has been widely used in the description and design of post-harvest facilities, including products and packaging (Defraeye et al, 2014;Delele et al, 2013a, b;Ferrua and Singh, 2009), storage facilities (Chourasia et al, 2007;Delele et al, 2009;Foster et al, 2006), and refrigerated transport (Moureh et al, 2009a, b;Tapsoba et al, 2007). This study addresses the optimization of the gas exchange system for transportation with CA.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…CFD simulation has been widely used in the description and design of post-harvest facilities, including products and packaging (Defraeye et al, 2014;Delele et al, 2013a, b;Ferrua and Singh, 2009), storage facilities (Chourasia et al, 2007;Delele et al, 2009;Foster et al, 2006), and refrigerated transport (Moureh et al, 2009a, b;Tapsoba et al, 2007). This study addresses the optimization of the gas exchange system for transportation with CA.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, a 2-D model was used to predict the influence of exhaust valve location, driving speed, and diameter of valve on gas exchange performance. To improve the airflow patterns in a ventilated enclosure, a 3-D model is useful to obtain considerable data in only one case (Foster et al, 2006;Tapsoba et al, 2007).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In reality the momentum of the air jet should be higher since the minimum momentum corresponds with the stability border. Therefore a safety factor between 1.3 and 2 is suggested for the outlet velocity [12].…”
Section: Characteristics Of An Air Curtainmentioning
confidence: 99%
“…The air flow rate through the curtain was measured with a tracer gas decay method [12,15,16,23,24]. A concentration of CO 2 tracer gas was released in the cooled room while the door was closed.…”
Section: Measurement Case Descriptionmentioning
confidence: 99%