2015
DOI: 10.1016/j.ajo.2015.01.025
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Pupil Size on Biometry Measurements Using the IOLMaster

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

9
21
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(32 citation statements)
references
References 29 publications
9
21
0
1
Order By: Relevance
“…Thus, no significant change in AL is produced in response to pupil dilation using both the IOLMaster 500 © and LENSTAR © [6][7][8][9][10]. The slight, though significant, increase in CCT observed in our study is consistent with the findings of other authors, who noted significant increases in CCT after pupil dilation with tropicamide eye drops [14,15].…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…Thus, no significant change in AL is produced in response to pupil dilation using both the IOLMaster 500 © and LENSTAR © [6][7][8][9][10]. The slight, though significant, increase in CCT observed in our study is consistent with the findings of other authors, who noted significant increases in CCT after pupil dilation with tropicamide eye drops [14,15].…”
Section: Discussionsupporting
confidence: 90%
“…In three studies examining the effect of pupil dilation in IOLMaster 500 © measurements [6][7][8], no effects were observed on AL and only one study reported a significant difference in pre-and post dilation MK data [6]. In addition, in the only one study in which the ACD was measured, this variable was found to increase after pupil dilation.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…12) Adler et al also indicated similar results. 17) These results were reasonable since SRK/T does not include ACD as a biometric parameter, which is significantly affected by pupil dilation,…”
Section: Resultsmentioning
confidence: 67%
“…They concluded that cycloplegia affected ACD and WTW but not AL or corneal curvature measurements. Adler et al showed there is no clinically significant effect of pupil dilation on the IOL Master measurements of AL, corneal power, and corresponding theoretical IOL calculated using the Sanders‐Retzlaff‐Kraff/Theoretical formula. Besides Lenstar and IOL Master 500, accurate and repeatable outcomes have been reported with IOL Master 700 as well .…”
Section: Discussionmentioning
confidence: 99%