2016
DOI: 10.1016/j.jfo.2016.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer

Abstract: Please cite this article in press as: Arriola-Villalobos P, et al. Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer. J Fr Ophtalmol (2016) Please cite this article in press as: Arriola-Villalobos P, et al. Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer. J Fr Ophtalmol (2016) P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

6
26
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(34 citation statements)
references
References 23 publications
6
26
2
Order By: Relevance
“…Unlike their study, we observed a significant increase in CCT and the difference between two studies might be attributable to topical drops. Arriola‐Villalobos et al also observed an increase in CCT obtained with IOL Master 700 after tropicamide installation. The mechanism of the increase in CCT remains unclear.…”
Section: Discussionmentioning
confidence: 85%
See 2 more Smart Citations
“…Unlike their study, we observed a significant increase in CCT and the difference between two studies might be attributable to topical drops. Arriola‐Villalobos et al also observed an increase in CCT obtained with IOL Master 700 after tropicamide installation. The mechanism of the increase in CCT remains unclear.…”
Section: Discussionmentioning
confidence: 85%
“…No significant difference was observed between pre‐dilation and post‐dilation WTW values in this study. Diversely, Arriola‐Villalobos et al found significant difference in WTW obtained with IOL Master 700 before and after pupil dilation with tropicamide. We provided pupil dilation by cyclopentolate but, in terms of WTW, the disagreement between studies is not attributable to either cyclopentolate or tropicamide.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…It is controversial whether pupil dilation influences WTW. While Huang et al 10) and Arriola-Villalobos et al 15) have insisted that WTW is affected by pupil dilation, the opposite result has been reported by Wang et al 8) Although the researchers attributed the discrepancy in the influence of pupil dilation on WTW to the examination error and imaging artifact, the real mechanism remains unknown.…”
Section: Resultsmentioning
confidence: 97%
“…3) Many studies have investigated the influence of pupil dilation on these biometric measurements. 8,[10][11][12][13][14][15][16] In a clinical setting, pupil dilation is a vital process of preoperative examination. Therefore, it is important to analyze its possible influence on PPR and recommended IOL power in third, fourth, and new generation IOL power calculation formulas, and to investigate the correlation between variables.…”
Section: Resultsmentioning
confidence: 99%