2015
DOI: 10.1109/tie.2015.2405058
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Phase-Shift Angle on a Delta-Connected Autotransformer Applied to a 12-Pulse Rectifier

Abstract: The delta-connected autotransformer with π/6 phase-shift angle is widely used in the multi-pulse rectifier when the output voltage of the autotransformer is approximately equal to its input voltage. If its output voltage is slightly greater than its input voltage, the equivalent kVA rating of the autotransformer increase rapidly, and each core limb of the autotransformer has five windings. The increase in winding number will increase the asymmetry and manufacture difficulty of the autotransformer. Therefore, t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
17
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 35 publications
(19 citation statements)
references
References 21 publications
2
17
0
Order By: Relevance
“…4. The configuration of the winding is based on the equations (4) and (5), and constants K 1 -K 22 . For example, the voltage Va1 is obtained by tapping a portion k 1 = 0.11607 of the voltage V CA and connecting one end of an approximate k 2 = 0.092128 of voltage V BC to this tap.…”
Section: The Proposed Forty-four Pulse Rectifiermentioning
confidence: 99%
“…4. The configuration of the winding is based on the equations (4) and (5), and constants K 1 -K 22 . For example, the voltage Va1 is obtained by tapping a portion k 1 = 0.11607 of the voltage V CA and connecting one end of an approximate k 2 = 0.092128 of voltage V BC to this tap.…”
Section: The Proposed Forty-four Pulse Rectifiermentioning
confidence: 99%
“…The proposed 36-pulse diode rectifier contains two three-phase diode-bridge rectifiers, the phase-shifting angle of the phase-shift transformer should be π/6 from the viewpoint of eliminating 5th and 7th harmonics [22]. As discussed in [23], when the phase-shifting angle is π/6, the winding configuration of delta-connected autotransformer shown in Figure 2a is the simplest and the delta-connected autotransformer has the least kVA rating. Figure 2b shows the phasor diagram of delta-connected autotransformer.…”
Section: Proposed 36-pulse Rectifier With Unconventional Iprmentioning
confidence: 99%
“…Due to the switching of power devices in three-phase inverters, the harmonics are generated and when these converters are integrated with system networks, the power quality of the system is affected. In order to reduce these harmonics, a comparative analysis is made between conventional 150, 180, 120 modes for SAB3 [9][10] with 14 vector groups of transformer as shown in Table 1. Figure 1 shows the SAB3 topology.…”
Section: Introductionmentioning
confidence: 99%