1986
DOI: 10.1111/j.1532-950x.1986.tb00216.x
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Fixation Pin Insertion on the Bone‐Pin Interface

Abstract: Smooth and partially threaded 3.12 mm (W inch) trochar-tipped Steinmann pins were inserted transversely through both diaphyseal cortices of eight mature canine tibias using five methods. Angular velocity (revolutions per minute) during insertion and temperature elevation due to friction during penetration of the second cortex were recorded. The force required for extraction of the pins from the bone and the histologic appearance of the bone-pin interface were determined for one-half of the pins 2 days after in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
63
0

Year Published

2000
2000
2024
2024

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(64 citation statements)
references
References 8 publications
1
63
0
Order By: Relevance
“…Inappropriate technique can lead to excessive heat generation resulting in thermal osteonecrosis and premature pin loosening. 21,37 Animal studies have shown that bone undergoes significant resorption when heated to 50°C for 60 seconds or longer, 38 and pin insertion with a high speed drilling results in significantly higher bone temperatures. It is therefore recommended that pins are placed at a slow speed (150rpm or less), as high speed placement reduces long term pin extraction forces when compared with low speed placement.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Inappropriate technique can lead to excessive heat generation resulting in thermal osteonecrosis and premature pin loosening. 21,37 Animal studies have shown that bone undergoes significant resorption when heated to 50°C for 60 seconds or longer, 38 and pin insertion with a high speed drilling results in significantly higher bone temperatures. It is therefore recommended that pins are placed at a slow speed (150rpm or less), as high speed placement reduces long term pin extraction forces when compared with low speed placement.…”
Section: Discussionmentioning
confidence: 99%
“…It is therefore recommended that pins are placed at a slow speed (150rpm or less), as high speed placement reduces long term pin extraction forces when compared with low speed placement. 2,21,36,37 A further technique factor is the forward drilling force, which can affect maximal cortical bone temperatures when drilling. 39 Again, this type of information was not available in a retrospective study.…”
Section: Discussionmentioning
confidence: 99%
“…Although IM pin resists bending equally well in all directions due to the proximity of the neutral axis, resistance to disruptive forces of shearing, torsion and compression is inadequate if used alone (5,11,18). When used together, ESF and IM pin are more resistant against these forces.…”
Section: Discussionmentioning
confidence: 99%
“…This was preferred, because previous studies show that high speed drills (or with low speed and excessive pressure) may cause thermal necrosis in the bones and because of the holes excessive enlargement for the pins resulting in premature loosening [18] . Soft tissue swelling is frequently seen between connecting bar and skin, postoperatively.…”
Section: şEnel Ergi̇n öZdemi̇r Ulusan Csebi̇ Dioszegi Bi̇lgi̇li̇mentioning
confidence: 99%