2019
DOI: 10.1016/j.athoracsur.2018.07.091
|View full text |Cite
|
Sign up to set email alerts
|

Early Clinical Outcomes of Hybrid Arch Frozen Elephant Trunk Repair With the Thoraflex Hybrid Graft

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
55
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(57 citation statements)
references
References 20 publications
1
55
0
Order By: Relevance
“…[4][5][6] Since 2018, Thoraflex Hybrid is our FET device of choice because of the advantages of the branched plexus configuration but LSA anastomosis remains its Achilles heel. 7 To address this, we debranch and selectively cannulate the LSA and LCA with interposition of 10/8 mm Dacron prosthesis avoiding direct cannulation F I G U R E 1 A custom-made Thoraflex Hybrid: (A) cerebral vessels branch (16 mm); (B) perfusion side branch (10 mm) and a Gelweave™ surgical graft: 1, perfusion side branch (10 mm); 2, innominate branch (10 mm); 3, left carotid branch (8 mm); 4, left subclavian branch (8 mm) F I G U R E 2 Homemade perfusion system driven by a single pump: 1, right intrathoracic subclavian artery perfusion (systemic perfusion); 2, left subclavian artery perfusion; 3, left carotid artery perfusion; 4, side branch systemic perfusion and optimizing bilateral cerebral perfusion (always trivascular).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…[4][5][6] Since 2018, Thoraflex Hybrid is our FET device of choice because of the advantages of the branched plexus configuration but LSA anastomosis remains its Achilles heel. 7 To address this, we debranch and selectively cannulate the LSA and LCA with interposition of 10/8 mm Dacron prosthesis avoiding direct cannulation F I G U R E 1 A custom-made Thoraflex Hybrid: (A) cerebral vessels branch (16 mm); (B) perfusion side branch (10 mm) and a Gelweave™ surgical graft: 1, perfusion side branch (10 mm); 2, innominate branch (10 mm); 3, left carotid branch (8 mm); 4, left subclavian branch (8 mm) F I G U R E 2 Homemade perfusion system driven by a single pump: 1, right intrathoracic subclavian artery perfusion (systemic perfusion); 2, left subclavian artery perfusion; 3, left carotid artery perfusion; 4, side branch systemic perfusion and optimizing bilateral cerebral perfusion (always trivascular).…”
Section: Discussionmentioning
confidence: 99%
“…Cerebral non-complete perfusion is minimized and related to the time of LCA anastomosis; HCA and operation times are shortened and probably contribute to a low incidence of major stroke, even in acute dissections (2.3% in acute aortic dissection [1/42]; 1.3%, in all thoraflex implant [1/74], our experience, data pending publication) compared to the literature (5%-14%). 7,8 With this device modification, the vessel lengths are more appropriate and the position of the neo-vessels in the chest avoids malpositioning and/or kinking, and facilitates sternum closure.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Of 64 studies reporting outcomes of patients included in this report 13–76 . The proportions of studies from Asia, Europe, and North America were 54.7%, 31.3%, and 10.9%, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Delirium was common and experienced by 25% of patients. The median intensive care unit (ICU) length of stay [IQR] was 3 [1,6] days, and the median hospital length of stay [IQR] was 10 [7, 17] days. There was no association between length of FET and SCI (un-adjusted OR: 1.01, 95% CI: 0.99-1.00, P=0.23).…”
Section: Early (In-hospital) Clinical Outcomesmentioning
confidence: 99%