2020
DOI: 10.1111/jocs.15208
|View full text |Cite
|
Sign up to set email alerts
|

A modified frozen elephant trunk hybrid device to facilitate supra‐aortic trunk anastomosis

Abstract: Reimplantation of the supra-aortic vessels can be challenging with Thoraflex Hybrid. A device modification made the vessel lengths more appropriate and the position of the neo-vessels in the chest avoided malpositioning and kinking and facilitated sternum closure; this may improve operating times as well as allowing complete and continuous cerebral trivascular perfusion and corrects positioning of the intrathoracic vessels.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 7 publications
0
8
0
Order By: Relevance
“…In one case, not included in this series, we successfully used a custom-made Thoraflex Hybrid, in which the plexus is separated from the main part of the prosthesis, to make anastomosis easier, improve operating times and correctly position the intra-thoracic vessels. 15 Overall survival for the entire cohort at 30 days was 90% (95% CI, 83.2-97.3), without statistically significant differences between emergency and elective surgery (87.9% vs. in emergency vs. 93.2% in chronic settings, p = .312).…”
Section: Resultsmentioning
confidence: 88%
“…In one case, not included in this series, we successfully used a custom-made Thoraflex Hybrid, in which the plexus is separated from the main part of the prosthesis, to make anastomosis easier, improve operating times and correctly position the intra-thoracic vessels. 15 Overall survival for the entire cohort at 30 days was 90% (95% CI, 83.2-97.3), without statistically significant differences between emergency and elective surgery (87.9% vs. in emergency vs. 93.2% in chronic settings, p = .312).…”
Section: Resultsmentioning
confidence: 88%
“…As previously reported by our group [18], in our institution, the right intrathoracic subclavian artery is routinely employed as the site for central cannulation. Its exposure is facilitated by extending the usual sternotomy incision in a small right supra-clavicular cervicotomy.…”
Section: Cannulation Strategymentioning
confidence: 74%
“…In our opinion, the claimed technical challenge of this technique should not represent a limit to its use in acute settings. The contemporary concept of specialized centers with a high volume of aortic surgery treating both chronic and acute aortic syndrome is now becoming dominant and possibly changing the surgical approach [18]. There is a substantial unanimity on the idea that patients affected by acute aortic syndromes may well gain advantages from treatment at dedicated specialized aortic centers, with significantly improved results and decreased mortality [44][45][46].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In one case, not included in this series, we successfully used a custom-made Thoraflex Hybrid, in which the plexus is separated from the main part of the prosthesis, in order to make anastomosis easier, improve operating times and correctly position the intra-thoracic vessels. 15 Overall survival for the entire cohort at 30 days was 90% (95% CI, 83.2-97.3), without statistically significant differences between emergency and elective surgery (87.9% vs. in emergency vs. 93.2% in chronic settings, P=0.312).…”
Section: Discussionmentioning
confidence: 88%