2018
DOI: 10.2200/s00828ed1v01y201802pel010
|View full text |Cite
|
Sign up to set email alerts
|

Dynamics and Control of DC-DC Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
17
0
3

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(20 citation statements)
references
References 7 publications
0
17
0
3
Order By: Relevance
“…Based on the bilinear z-transform given in Eq.3a and the converter parameters given in table-2, the s-domain transfer (3a) ) 1 ( The parts of the system that model the digital controller [17][18][19][20][21][22] include: A/D converter, discrete time compensator, and digital PWM. Also by using the direct form II realization method to reduce the number of delays, As a result, the hardware description of our compensator can be implemented as following: Fig.7 shows the realized digital compensator using direct form II method…”
Section: Digital Compensatormentioning
confidence: 99%
“…Based on the bilinear z-transform given in Eq.3a and the converter parameters given in table-2, the s-domain transfer (3a) ) 1 ( The parts of the system that model the digital controller [17][18][19][20][21][22] include: A/D converter, discrete time compensator, and digital PWM. Also by using the direct form II realization method to reduce the number of delays, As a result, the hardware description of our compensator can be implemented as following: Fig.7 shows the realized digital compensator using direct form II method…”
Section: Digital Compensatormentioning
confidence: 99%
“…Foundation of SSA was laid down in [7] and later extended in [8,9,10], as well as many other publications. Theory of SSA has been studied in many text books for instance see [10] and [11]. SSA has two important steps: averaging and linearization.…”
Section: Introductionmentioning
confidence: 99%
“…SSA has two important steps: averaging and linearization. The SSA procedure can be summarized as follows [11]:…”
Section: Introductionmentioning
confidence: 99%
“…1 shows the electrical schematic of a DC-DC TLBC. The DC-DC converters present a nonlinear dynamic behavior, which increases their modeling and control complexity [2].…”
Section: Introductionmentioning
confidence: 99%
“…is the switching frequency. 1 d and2 d are defined as the duty ratios respectively. They lead to identical control signal but shifted by 180 degrees.…”
mentioning
confidence: 99%