2021
DOI: 10.1186/s40510-021-00362-8
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging

Abstract: Background Based on the role of properties of aligner materials on their efficiency, we aimed to assess their thermomechanical properties after thermoforming and simulated aging. Methods In this experimental study, 96 samples of polyethylene terephthalate glycol (PETG) aligners (Duran and Erkodur) were prepared and divided to three groups: control (C), after thermoforming (T), after thermoforming and aging (TA). Thermoforming was done through 3D-pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
45
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(55 citation statements)
references
References 28 publications
0
45
0
3
Order By: Relevance
“…This study contrasts with Delaie's study (Dalaie et al, 2021), which investigates the thermomechanical properties of two PET-G aligners of two different thicknesses, 1 and 0.8 mm, in response to seeing in both types, the hardness decreases by about 7.6% after thermoforming.…”
Section: Discussionmentioning
confidence: 72%
See 4 more Smart Citations
“…This study contrasts with Delaie's study (Dalaie et al, 2021), which investigates the thermomechanical properties of two PET-G aligners of two different thicknesses, 1 and 0.8 mm, in response to seeing in both types, the hardness decreases by about 7.6% after thermoforming.…”
Section: Discussionmentioning
confidence: 72%
“…The study of Dalaie et al investigated the thermomechanical properties of two PET-G aligners of two different thicknesses, 1 and 0.8 mm, in response to thermoforming; it has been seen that in both types, the hardness decreases by about 7.6% after thermoforming, but there are no significant differences in hardness into the two types of aligners. The reduction of thickness decreases after thermoforming in both types of aligners, which justifies the reduction of flexural modulus (Dalaie et al, 2021). Comparing the flexural modulus of Duran with a thickness of 0.75 and Duran 1mm, the first modulus increases and the second decrease, meaning that with increasing thickness of the Pet-G sheets, the bending modulus decreases (Dalaie et al, 2021).…”
Section: The Influence Of Thermoforming Processmentioning
confidence: 74%
See 3 more Smart Citations