2013
DOI: 10.1109/jssc.2013.2272352
|View full text |Cite
|
Sign up to set email alerts
|

Double-Quadrature UWB Receiver for Wide-Range Localization Applications With Sub-cm Ranging Precision

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(15 citation statements)
references
References 16 publications
0
15
0
Order By: Relevance
“…Additionally, the majority of the references presented in this survey are listed and categorized in TABLE VI including the articles that will be discussed next. [23], [26], [33] - [35] UWB surveys [37], [38] Implemented UWB systems [39] - [61] Ranging and positioning [44], [50], [62] - [70] Medical and healthcare [71] - [81] Interference and coexistence studies [82] - [90] Synchronization [91] - [93], [95] Regarding the next sections, the division of topics is based on general frameworks of research. The presentation order follows the popularity of the topic measured by the number of articles found and presented here.…”
Section: Compact Comparison Of the Standardsmentioning
confidence: 99%
“…Additionally, the majority of the references presented in this survey are listed and categorized in TABLE VI including the articles that will be discussed next. [23], [26], [33] - [35] UWB surveys [37], [38] Implemented UWB systems [39] - [61] Ranging and positioning [44], [50], [62] - [70] Medical and healthcare [71] - [81] Interference and coexistence studies [82] - [90] Synchronization [91] - [93], [95] Regarding the next sections, the division of topics is based on general frameworks of research. The presentation order follows the popularity of the topic measured by the number of articles found and presented here.…”
Section: Compact Comparison Of the Standardsmentioning
confidence: 99%
“…However, the development of high-accuracy IPS has been limited by the complexity and the cost of indoor real-time localization solutions. Hence, the motivation is high to develop indoor real-time positioning systems that combine sub-cm precision, low cost and low power requirements [6].…”
Section: Indoor Positioning Systemsmentioning
confidence: 99%
“…As a result, the amplitude after the beamforming decreases, while the signal is moving further away from the desired direction. Since the ΔΣ [6] applications. Novel methods are developed to achieve better performance.…”
Section: Duty-cyclementioning
confidence: 99%
“…This work demonstrates the best measured precision, consistent mm-precision over 4m range, while offering competitive performance at other aspects. In a broader context, UWB CMOS implementation can also achieve mm precision [7], [28]. However, since the signal generation is not addressed in this receivercentric system, a fair comparison on the transmitter is not feasible.…”
Section: Ranging Performancementioning
confidence: 99%