Dose rate assessment in complex geometries

Abstract: A code developed for calculating dose rate maps in scenarios with complex geometries and gamma radiation sources is presented in this work. It is based on the point kernel method. The code computes photon flux and dose rate in preselected positions due to volumetric radioactive sources in the presence of other nonemitting materials acting as shielding. Buildup factors are considered to account for radiation scattering effects, using the Geometric-Progression formula in the fitting function. The major advantage… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…The third set of experiments was designed to illustrate the performance accuracy of VRBAM compared with VRBM and MCNP. Three basic scenarios were considered in the experiment, and they were: (A) no shielding, (B) shielding scenario, both of which were already used as benchmark scenarios in dose rate experiments in CIDEC (Vela et al 2006) and VRBM (Chao et al 2018), (C) surface-source scenario. The results from MCNP were generated by running the code for two hours and those from VRBAM and VRBM are averaged over 100 simulations.…”
Section: Accuracy Of Dose Rate Calculation Testmentioning
confidence: 99%
See 2 more Smart Citations
“…The third set of experiments was designed to illustrate the performance accuracy of VRBAM compared with VRBM and MCNP. Three basic scenarios were considered in the experiment, and they were: (A) no shielding, (B) shielding scenario, both of which were already used as benchmark scenarios in dose rate experiments in CIDEC (Vela et al 2006) and VRBM (Chao et al 2018), (C) surface-source scenario. The results from MCNP were generated by running the code for two hours and those from VRBAM and VRBM are averaged over 100 simulations.…”
Section: Accuracy Of Dose Rate Calculation Testmentioning
confidence: 99%
“…It often uses Monte Carlo techniques to obtain parameters and select source points, and it treats radiation transport deterministically. These methods have been exploited by many researchers (Breismeister 2000, Vela et al 2006, Chao et al 2018.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This second test compares dose rate results for a specific setup already used as a benchmark case in previous Dose rate experiments published in this journal [13].…”
Section: B Case 2: Water Cube ( 137 Cs Source) Computer Simulationsmentioning
confidence: 99%
“…Alternatively, the deterministic PK methods can be used [11,12,13]. They are well known in the scientific community, and in particular in the nuclear physics field.…”
Section: Introductionmentioning