Distributed Partial Discharge Detection in a Power Transformer Based on Phase-Shifted FBG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
42
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(42 citation statements)
references
References 30 publications
0
42
0
Order By: Relevance
“…Optical fiber needs to be compatible with the oil inside the casing and needs to withstand high temperatures. The flexibility and resistance of fiber optics are among the main advantages comparing to other optical devices, but in order to grant the long term protection and to avoid accidental destruction of the sensor, the use of high temperature resistant polymers has been reported recently for different kinds of optical sensors [16,17]. However, for tests with Epstein frame, where oil is not present, this technology is an optimal alternative compared with resistive strain gauges.…”
Section: Background and Related Workmentioning
confidence: 99%
“…Optical fiber needs to be compatible with the oil inside the casing and needs to withstand high temperatures. The flexibility and resistance of fiber optics are among the main advantages comparing to other optical devices, but in order to grant the long term protection and to avoid accidental destruction of the sensor, the use of high temperature resistant polymers has been reported recently for different kinds of optical sensors [16,17]. However, for tests with Epstein frame, where oil is not present, this technology is an optimal alternative compared with resistive strain gauges.…”
Section: Background and Related Workmentioning
confidence: 99%
“…84 Another method to improve the sensitivity is to use a phase shift FBG (PS-FBG). 85,86 Because the PS-FBG exhibits a sharp resonance, the ultrasonic sensitivity is improved compared with the FBG. It has been reported that the sensitivity of PS-FBG-based ultrasonic sensor is 8.46 dB higher than PZT sensor between 50 to 400 kHz.…”
Section: Partial Discharge Monitoringmentioning
confidence: 99%
“…It has been reported that the sensitivity of PS-FBG-based ultrasonic sensor is 8.46 dB higher than PZT sensor between 50 to 400 kHz. 86…”
Section: Partial Discharge Monitoringmentioning
confidence: 99%
“…Regarding the breakdown discharge detection requirement of large-scale HV equipment, fiber Bragg grating (FBG)-based discharge detection system are proposed [17,18]. However, the multiplexing of multiple FBGs would increase complexity of the detection system.…”
Section: Introductionmentioning