Diagnostics of low-pressure discharge argon plasma by multi-optical emission line analysis based on the collisional-radiative model

Abstract: This work is focused on diagnostics of electron temperature (1.0 eV–3.8 eV) and electron density (1.0 × 109 cm−3–5.0 × 1012 cm−3) of low-pressure (133 Pa) discharge argon plasma by optical emission spectroscopic (OES) measurement. The diagnostic method using multi-emission lines was analyzed. First, the excitation-kinetic models were obtained by extracting dominant kinetic processes based on the collisional-radiative model. Then, the diagnostic equations for wide range of electron temperature and density were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
22
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 13 publications
(23 citation statements)
references
References 26 publications
(39 reference statements)
0
22
1
Order By: Relevance
“…In order to realize such an OES measurement, following two conditions must be satisfied in the modeling of the excitation kinetics [74]:…”
Section: Extraction Of Dominant Elementary Processesmentioning
confidence: 99%
See 3 more Smart Citations
“…In order to realize such an OES measurement, following two conditions must be satisfied in the modeling of the excitation kinetics [74]:…”
Section: Extraction Of Dominant Elementary Processesmentioning
confidence: 99%
“…Based on these approximations, dominant terms are to be extracted from the RHS of Equations (8) -(9) [39,[72][73][74]. If the above model is made to cover a wide range of the electron temperature and density, too many parameters must be extracted from the summation of the RHS of these equations.…”
Section: Extraction Of Dominant Elementary Processesmentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, there are few reports on the differences caused by the data analysis method on OES measurement. Some types of OES measurements of T e or N e for nonequilibrium low-temperature plasma have been proposed, e.g., the dominant elementary process extraction method [24]- [26], line-pair method [3], [27], and excitation temperature conversion method [28]. The dependence of diagnostic results on the spectrum analysis methods of OES measurements is interesting for the improvement of OES measurements.…”