2019
DOI: 10.1109/tsg.2017.2743158
|View full text |Cite
|
Sign up to set email alerts
|

DGs for Service Restoration to Critical Loads in a Secondary Network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
61
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 112 publications
(77 citation statements)
references
References 32 publications
0
61
0
2
Order By: Relevance
“…The system performance function has been defined as the total power that is supplied to critical loads based on their priority. Similar metrics have been proposed in [55]- [57].…”
Section: B Metrics Based On Resilience Featuresmentioning
confidence: 86%
See 1 more Smart Citation
“…The system performance function has been defined as the total power that is supplied to critical loads based on their priority. Similar metrics have been proposed in [55]- [57].…”
Section: B Metrics Based On Resilience Featuresmentioning
confidence: 86%
“…The effect of DG to speed up the restoration processes during and after extreme events has been presented in [78]. A three-step look-ahead load restoration strategy using synchronized DG through restoring critical loads after a major natural disaster has been developed in [57], [99]. In [104], the authors have developed a distribution service restoration model to generate optimal switching sequence based on remotely and manually controlled switches and dispatchable DGs in extreme events.…”
Section: A Operation-based Resilience Enhancement Methodsmentioning
confidence: 99%
“…The heating system model comprises of the nodal supply and return temperature differences (7)-(8), nodal heating power demand equation (9), nodal heating power source equation (10), nodal water mass balance equation (11) and head loss equation (12) [16]. It is noted that sign 1 (m ba ) in (11) is the sign function, where sign 1 (m ba ) =1 when m ba >0, and otherwise sign 1 (m ba )=0; and sign 2 (m ab ) in (12)…”
Section: Heating Systemmentioning
confidence: 99%
“…As a basic tool, energy flow calculation (EFC) plays a significant role in steady-state analysis of MESs, such as day-ahead dispatch [9], static security analysis [10] and service restoration [11]. However, high-order nonlinear EFC models are challenging to solve due to the limited information sharing between subsystems, which are generally managed by different operators.…”
Section: Introductionmentioning
confidence: 99%
“…Contudo, assim como acontece nas radiais, estas topologias não foram projetadas para agregarem geradores no lado dos consumidores, pois esta integração é referida como desafiadora, podendo levar à degradação dos perfis de tensão, acometer sobrecorrentes nos ramos da rede elétrica, além de provocar o disparo inadequado dos protetores de rede (Network Protectors), dispositivos de proteção que não permitem fluxo de potência no sentido contrário ao convencional, ou seja, partindo das cargas em direção à subestação (IEEE.1547.6, 2011; IEEE.C57.12.44, 1.1. Motivação XU et al, 2017). Este é um dos fatores, juntamente com o elevado custo de investimento da estrutura, que demanda estudos precisos para contornar os desafios impostos.…”
Section: Introductionunclassified