2017
DOI: 10.1016/j.foodcont.2016.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Development of one-step reverse transcription loop-mediated isothermal amplification for norovirus detection in oysters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(23 citation statements)
references
References 51 publications
0
23
0
Order By: Relevance
“…In addition, Moore and Jaykus [108] developed a rapid (<30 min) RPA assay for the detection of HuNoV RNA from outbreak samples, with a LOD of 3.4 log 10 gc. Jeon et al [109] developed a one-step RT-LAMP assay for the detection of GI and GII HuNoV and found that one step RT-LAMP was 10~100 times more sensitive than real time RT-PCR. A colorimetric RT-LAMP assay with a metal ion-binding indicator dye (hydroxynaphthol blue dye) was reported to have a sensitivity of 10 3 gc per reaction and a detection rate of 94.83% in detection of GII NoV [110].…”
Section: Isothermal Amplification Methodsmentioning
confidence: 99%
“…In addition, Moore and Jaykus [108] developed a rapid (<30 min) RPA assay for the detection of HuNoV RNA from outbreak samples, with a LOD of 3.4 log 10 gc. Jeon et al [109] developed a one-step RT-LAMP assay for the detection of GI and GII HuNoV and found that one step RT-LAMP was 10~100 times more sensitive than real time RT-PCR. A colorimetric RT-LAMP assay with a metal ion-binding indicator dye (hydroxynaphthol blue dye) was reported to have a sensitivity of 10 3 gc per reaction and a detection rate of 94.83% in detection of GII NoV [110].…”
Section: Isothermal Amplification Methodsmentioning
confidence: 99%
“…Table 2. Comparison between PCR and loop-mediated isothermal amplification (LAMP) reactions [37,[40][41][42].…”
Section: A Potential Candidate For Rapid Detection Of Sars-cov-2: Loomentioning
confidence: 99%
“…For virus detection, for example, influenza [40] or human norovirus, LAMP assay offers one-step detection [41]. Sample preparation steps are simplified.…”
Section: Always Requires Sample Concentration and Preparation (Time-cmentioning
confidence: 99%
See 1 more Smart Citation
“…As a response to the urgent demand for more accurate and reliable detection, here the gene segments of NoV GII was specifically employed as the model target [39]. In spite of their high sensitivity, earlier reports like electron microscopy [40,41], immunology-based detection (radioimmunoassay (RIA) [42,43], enzyme-linked immunosorbent assays (ELISA) [44,45]) and nucleic acids biomarkers detection based on gene amplification techniques (PCR [46,47], nucleic acid sequence-based amplification (NASBA) [48,49], LAMP [50,51]) always lack of specificity and false positive results can easily arise. Herein, the powerful exponential amplification of LAMP results in ultrasensitive NoV gene detection with a detection limit of 30 copies, while the HCR gives rise to very good specificity and reliable signal changes in all kinds of readouts.…”
Section: Introductionmentioning
confidence: 99%