2017
DOI: 10.1002/jssc.201700628
|View full text |Cite
|
Sign up to set email alerts
|

Development and evaluation of microwave‐assisted and ultrasound‐assisted methods based on a quick, easy, cheap, effective, rugged, and safe sample preparation approach for the determination of bisphenol analogues in serum and sediments

Abstract: Microwave- and ultrasound-assisted methods based on a quick, easy, cheap, effective, rugged, and safe sample preparation approach followed by high-performance liquid chromatography with tandem mass spectrometry were developed for the simultaneous determination of eight bisphenol analogues in serum and sediment. The developed methods provided satisfactory extraction efficiency for the energy provided by microwaves and ultrasound. Compositions of commercial sorbents (primary secondary amine, MgSO , octadecyl-mod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 43 publications
0
5
0
Order By: Relevance
“…The MDL for CECs ranged between 0.002 and 1.93 µg/kg by the proposed method. The sensitivity of the method was better for most of the CECs in comparison with different versions of the QuEChERS methods (Berlioz‐Barbier et al ; Carmona et al ; Santos et al ; Song et al ). Corresponding to the recoveries discussed earlier in this section, the sensitivity of gemfibrozil, naproxen, paracetamol (acetaminophen), caffeine, carbamazepine, and miconazole was higher for the proposed method than for the USEPA method (US Environmental Protection Agency ).…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…The MDL for CECs ranged between 0.002 and 1.93 µg/kg by the proposed method. The sensitivity of the method was better for most of the CECs in comparison with different versions of the QuEChERS methods (Berlioz‐Barbier et al ; Carmona et al ; Santos et al ; Song et al ). Corresponding to the recoveries discussed earlier in this section, the sensitivity of gemfibrozil, naproxen, paracetamol (acetaminophen), caffeine, carbamazepine, and miconazole was higher for the proposed method than for the USEPA method (US Environmental Protection Agency ).…”
Section: Resultsmentioning
confidence: 96%
“…The sensitivity of the proposed method was compared on the basis of MDL with some other versions of QuEChERS (Berlioz-Barbier et al 2014;Carmona et al 2014;Santos et al 2016;Song et al 2017), MSPD (Li et al 2016), and the USEPA method (US Environmental Protection Agency 2007) as given in Table 5. Predominantly, the proposed method showed promise by achieving high sensitivity for all the CECs.…”
Section: Methods Comparisonmentioning
confidence: 99%
“…Similarly, MAE was utilized to remove TBBPA from plastic waste within 30 min using hexane/Isopropanol and hexane/ethanol with recovery rate greater than 73% [ 147 ]. The introduction of ultrasound and microwave energy into QuEChERS technique increased the efficiency of extracting bisphenols including TBBPA significantly in serum and sediment samples [ 148 ]. BPA and TBBPA were detected in commercial milk samples by a rapid and facile microwave assisted ionic liquid microextraction (MAILME) method.…”
Section: Emerging Methods For Tetrabromobisphenol a Detection And Tre...mentioning
confidence: 99%
“…Various matrices are in the spotlight of different research groups for the determination of BPA and its analogs in literature. These include environmental samples, food samples as well as matrices of bioanalytical interest [8][9][10][11]. Different analytical techniques have been used for the determination of bisphenol analogs in numerous samples.…”
Section: Introductionmentioning
confidence: 99%