2008
DOI: 10.1262/jrd.19166
|View full text |Cite
|
Sign up to set email alerts
|

Development and Evaluation of a Rapid Enzyme-immunoassay System for Measurement of the Urinary Concentration of Estrone-3-glucuronide in a Female Giant Panda (Ailuropoda melanoleuca)

Abstract: Abstract. To detect estrus for reproductive management, and to determine the relationship between urinary estrogen and estrous behavior, in a female giant panda, we developed and evaluated a rapid enzyme immunoassay (EIA) system for urinary Estrone-3-glucuronide (E1G) using commercial reagents. The developed EIA system took only around 3 hours, including all procedures to obtain a result. It indicated good reproducibility (intra-assay CV of 5.16%, interassay CV of 15.4%) and sensitivity (lowest standard concen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 27 publications
(35 reference statements)
0
10
0
Order By: Relevance
“…Urine supernatant was used for the assays. Urine samples were Urine concentrations of E 1 G and PdG were assayed using an enzyme immunoassay using the same methods and reagents as described by Hama et al 22,23 The polyclonal E 1 G antiserum (FKA-224E;…”
Section: Hormone and Protease Assaysmentioning
confidence: 99%
“…Urine supernatant was used for the assays. Urine samples were Urine concentrations of E 1 G and PdG were assayed using an enzyme immunoassay using the same methods and reagents as described by Hama et al 22,23 The polyclonal E 1 G antiserum (FKA-224E;…”
Section: Hormone and Protease Assaysmentioning
confidence: 99%
“…Immediately after collection, each urine sample was stored at )35°C for further analysis. Urinary steroid hormones were analyzed by EIA and the creatinine concentrations were measured using a modified-Jaffe's reaction according to the methods described elsewhere [1,11]. Concentrations of the hormones were calculated as ng/mg creatinine (Crmg).…”
Section: Hormone Analysismentioning
confidence: 99%
“…The concentrations of standards used in this study were between 0.03125 and 2.0 ng/well. The EIA buffer, coating buffer, wash buffer, substrate buffer and 2nd antibody used in the present study were the same as those used in a previous report [4]. A plate was coated with 2nd antibody and washed with wash buffer 2 times.…”
Section: Animalmentioning
confidence: 99%