2012
DOI: 10.1016/j.jchromb.2012.05.030
|View full text |Cite
|
Sign up to set email alerts
|

Determination of phenylethanolamine A in animal hair, tissues and feeds by reversed phase liquid chromatography tandem mass spectrometry with QuEChERS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 16 publications
0
11
0
Order By: Relevance
“…The performances of the developed method for the analysis of β‐agonists in animal feeds were compared to those of other reports as shown in Table S3. In this work the extraction solvent volume was smaller than almost all other reports and the extraction time (10 min without a pump) was shorter than most other reports . In addition it also provided better recoveries than some methods as well as lower RSDs.…”
Section: Resultsmentioning
confidence: 72%
“…The performances of the developed method for the analysis of β‐agonists in animal feeds were compared to those of other reports as shown in Table S3. In this work the extraction solvent volume was smaller than almost all other reports and the extraction time (10 min without a pump) was shorter than most other reports . In addition it also provided better recoveries than some methods as well as lower RSDs.…”
Section: Resultsmentioning
confidence: 72%
“…For the detection of PA, the Ministry of Agriculture of China issued a standard analytical method using HPLC‐MS/MS . Recently, there was a report of the LC‐MS/MS for the detection PA in animal hair, tissues and feeds . Generally, chromatographic methods are accurate; however, they are high cost and time‐consuming because of expensive instrument and extensive sample preparation.…”
Section: Introductionmentioning
confidence: 99%
“…18 Recently, there was a report of the LC-MS/MS for the detection PA in animal hair, tissues and feeds. 19 Generally, chromatographic methods are accurate; however, they are high cost and time-consuming because of expensive instrument and extensive sample preparation. Immunoassays are analytical methods which are based on the specific interaction between an antibody and corresponding antigen.…”
Section: Introductionmentioning
confidence: 99%
“…An LC‐MS/MS method is developed to detect PEAA in swine muscle (Sun and Yan ). A UHPLC‐ESI‐MS/MS with QuEChERS method is developed to detect PEAA in animal hair, tissues, and feed (Zhang and others ). A method of direct competitive enzyme‐linked immunosorbent assay (ELISA) is reported to detect PEAA residues in urine samples (Bai and others ).…”
Section: Introductionmentioning
confidence: 99%