1969
DOI: 10.1039/an9699400681
|View full text |Cite
|
Sign up to set email alerts
|

Determination of moisture in fertilisers and materials insoluble in methanol

Abstract: The moisture content of a fertiliser as manufactured has a significant effect on its tendency to cake during storage. The lower the moisture content the better, but on the other hand any unnecessary drying leads to extra costs in manufacture, and therefore a rapid, reliable and accurate method for the determination of moisture is necessary. Of those available, titration with Fischer reagent is of the most general application; oven drying, for example, cannot be used with fertilisers containing ammonium nitrate… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

1970
1970
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 0 publications
0
4
0
1
Order By: Relevance
“…In contrast, KF titration determines the total water content automatically by means of a chemical reaction. 5,6 In this case the titration curve has a characteristic shape, identified in other cases. 7 In order to explain urea caking, it is essential to know the water distribution in the grains.…”
Section: Introductionmentioning
confidence: 73%
See 1 more Smart Citation
“…In contrast, KF titration determines the total water content automatically by means of a chemical reaction. 5,6 In this case the titration curve has a characteristic shape, identified in other cases. 7 In order to explain urea caking, it is essential to know the water distribution in the grains.…”
Section: Introductionmentioning
confidence: 73%
“…The mass loss of the fertiliser during oven heating does not necessarily reflect the true water content, since only volatile substances are detected, while bound water escapes detection. In contrast, KF titration determines the total water content automatically by means of a chemical reaction 5, 6. In this case the titration curve has a characteristic shape, identified in other cases 7…”
Section: Introductionmentioning
confidence: 99%
“…Apparatus for manual (174, %10) and automatic (49,100,294) biamperometric titration has been described. A universal titrator that uses the third derivative of the input signal has been patented (80).…”
Section: Apparatus and Methodologymentioning
confidence: 99%
“…Perlu penentuan kadar air yang sesuai tidak terlalu tinggi maupun rendah. Kadar air mungkin berpengaruh pada kemungkinan timbulnya mekanisme penggumpalan saat penyimpanan (Heslop, Skinner and Docherty, 1969;Hignett, 1985). Rhizobium carrier based dan Biofertilizers disarankan digunakan dalam jangka waktu 4 bulan penyimpanan terkait dengan jumlah mikrobia yang masih lebih banyak sehingga kualitas masih cukup baik.…”
Section: Metode Penelitianunclassified