2020
DOI: 10.1016/j.colsurfb.2020.111030
|View full text |Cite
|
Sign up to set email alerts
|

Determination of chondroitin sulfate in synovial fluid and drug by ratiometric fluorescence strategy based on carbon dots quenched FAM-labeled ssDNA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 45 publications
0
3
0
Order By: Relevance
“…45 The shoulder peak was assigned to the specific stretching vibration of C�O at about 1648 cm −1 . 46 The broad bands at 3081 and 3282 cm −1 suggested the existence of amino (−NH 2 ) and hydroxy (−OH) groups. FTIR confirmed the doping effect of the nitrogen element and the presence of the abundance of hydrophilic groups in SP-CDs.…”
Section: T H Imentioning
confidence: 99%
See 1 more Smart Citation
“…45 The shoulder peak was assigned to the specific stretching vibration of C�O at about 1648 cm −1 . 46 The broad bands at 3081 and 3282 cm −1 suggested the existence of amino (−NH 2 ) and hydroxy (−OH) groups. FTIR confirmed the doping effect of the nitrogen element and the presence of the abundance of hydrophilic groups in SP-CDs.…”
Section: T H Imentioning
confidence: 99%
“…In the FTIR spectra (Figure D), the two peaks at 1118 and 1560 cm –1 were attributed to the stretching vibration of C–N–C and the bending vibration of N–H, respectively . The shoulder peak was assigned to the specific stretching vibration of CO at about 1648 cm –1 . The broad bands at 3081 and 3282 cm –1 suggested the existence of amino (−NH 2 ) and hydroxy (−OH) groups.…”
mentioning
confidence: 97%
“…One of the promising solutions to tackle the low accuracy and stability of the fluorescence detection methods is to use ratiometric fluorescence sensors where the intensities of two or more wavelengths are being measured. Ratiometric fluorescence sensors have higher response stability and have been used widely for the detection of various drugs. Most of the carbon quantum-dot-based fluorescence sensors rely on single-wavelength fluorescence emission, which has certain limitations . The dual-emissive CQDs are mostly prepared by doping specific elements using complex thermal and hydrothermal routes. , Therefore, there is a growing interest in the preparation of dual-emissive CQDs for ratiometric fluorescence sensors.…”
Section: Introductionmentioning
confidence: 99%