2007
DOI: 10.1365/s10337-007-0392-6
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Anomalin and Deltoin in Seseli resinosum by LC Combined with Chemometric Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Isolation and purification procedures of anomalin are also summarized in Table 1. As can be seen, anomalin was obtained from either aerial part and roots of the plant by extraction with petroleum ether, [36,56,57,60,68] hexane, [59,62,[64][65][66][67] diethyl ether, [70] chloroform, [51] methanol, [24,26,38,39,45 -50,52 -54,61,69,70] ethanol, [40,44,55,73,74] acetone, [41,[57][58][59] etc. at room temperature or by reflux.…”
Section: Sources and Isolationmentioning
confidence: 99%
“…Isolation and purification procedures of anomalin are also summarized in Table 1. As can be seen, anomalin was obtained from either aerial part and roots of the plant by extraction with petroleum ether, [36,56,57,60,68] hexane, [59,62,[64][65][66][67] diethyl ether, [70] chloroform, [51] methanol, [24,26,38,39,45 -50,52 -54,61,69,70] ethanol, [40,44,55,73,74] acetone, [41,[57][58][59] etc. at room temperature or by reflux.…”
Section: Sources and Isolationmentioning
confidence: 99%
“…In mass spectra, angular plots between loadings characteristic of individual compounds and the remaining diagnostic masses revealed further mass spectral structure [Zissis et al,1999]. Liquid chromatography-chemometric methods [LC-Partial least squares (LC-PLS), LCprinciple component regression (LC-PCR) and LC-artificial neural network (LC-ANN)] were developed for the determination of anomalin (ANO) and deltoin (DEL) in the root by Alev Tosun et al [ Tosun et al,2007]. Firstly, chemometric conditions were optimized by testing different mobile phases at various proportions of solvents with various flow rates in different wavelengths by using a normal phase column to obtain the best separation and recovery results.…”
Section: Chemometrics Investigations Using Photo Diode Array Detectionmentioning
confidence: 99%
“…Nowadays, chemometric methods, particularly partial least squares (PLS) and principal component regression (PCR), have been used as chemometric powerful tools to quantify two or more active substances in their mixtures using spectrophotometric data. However, some application of the chemometric calibration techniques in the chromatographic analysis of complex samples were reported 10–12.…”
Section: Introductionmentioning
confidence: 99%