Design of a Flat Field Spectrometer for Soft X-Ray Emission Spectroscopy

Abstract: A spectrometer for soft X-ray emission spectroscopy was designed and constructed. The aims of this spectrometer are high detection efficiency and realizing the energy resolution of 1000 (E/ΔE) in a compact size. To satisfy these requirements, a flat field spectrometer with a varied line spacing grating and a CCD detector was chosen. Furthermore, the configuration without the entrance slit was employed. For compact flat field spectrometers, the spectral dispersion on the detector is sometimes smaller than the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 42 publications
(23 citation statements)
references
References 12 publications
(10 reference statements)
0
23
0
Order By: Relevance
“…Although several new instruments for soft X-ray emission have been taken into operation in recent years [7][8][9][10], the acceptance angle limitation of spherical optics at grazing incidence has not been extensively addressed. Improved resolution has been achieved by a combination of up-scaling and increasing grating groove density, but at the expense of sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Although several new instruments for soft X-ray emission have been taken into operation in recent years [7][8][9][10], the acceptance angle limitation of spherical optics at grazing incidence has not been extensively addressed. Improved resolution has been achieved by a combination of up-scaling and increasing grating groove density, but at the expense of sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…SXE spectroscopy was performed with an 800 meV energy resolution. The design and performance of the SXE spectrometer is described in detail elsewhere [9]. First-principles calculations based on the density functional theory with a generalized gradient approximated correction were also performed to evaluate the local density of states of the valence level and the interface structure and properties [10].…”
mentioning
confidence: 99%
“…XAS at the Mn 2p edge was performed in the total electron yield mode and normalized by the photocurrent from a clean gold mesh. RXES spectra were recorded with a high-resolution grazing-incidence grating Rowland-mount spectrometer in which the energy resolution was set to be 0.7 eV [5]. RXES measurements were carried out with the depolar- ized configuration.…”
Section: Methodsmentioning
confidence: 99%