2009
DOI: 10.1016/j.nima.2008.12.227
|View full text |Cite
|
Sign up to set email alerts
|

Novel instruments for ultra-soft X-ray emission spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
9
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 8 publications
1
9
0
Order By: Relevance
“…This type of high resolution spectroscopy has been reported elsewhere using different wavelengths. 30,31 For the spatial coherence, we measure l coh % 12% in the horizontal and l coh % 15% in the vertical direction which is well within previously reported values. Following recent computational studies, the spatial coherence is reduced for high electron bunch currents (in this work >2 kA), which are typically present if high pulse energies are requested.…”
supporting
confidence: 84%
“…This type of high resolution spectroscopy has been reported elsewhere using different wavelengths. 30,31 For the spatial coherence, we measure l coh % 12% in the horizontal and l coh % 15% in the vertical direction which is well within previously reported values. Following recent computational studies, the spatial coherence is reduced for high electron bunch currents (in this work >2 kA), which are typically present if high pulse energies are requested.…”
supporting
confidence: 84%
“…3 Recently, designs employing a RLS-PG and two parabolic mirrors have been described which also rely on a MCP detector. 4,5 Ways have been found around the CCD-Rowland geometry mismatch. One is to use a MCP in combination with an image intensifier-converter coupled to a CCD.…”
Section: A Optical Schemesmentioning
confidence: 99%
“…The optical design of the SXE spectrometer is based on previously developed grazing incident flat field spectrometers using a varied line spacing (VLS) grating that compromises high energy resolution and high detection efficiency. 7,21 Their features are summarized in Fig. 2.…”
Section: Optimization Of Optical Geometry and Grating Parameters Omentioning
confidence: 99%
“…25 An image processing technique called super-resolution reconstruction is applied to the detector. 7,26 Cylindrical gratings are used instead of spherical gratings in order to reduce spherical aberration that may cause severe distortion of the focal line which broadens the line image at both sides of the detector resulting from subtle misalignment of the detector. Thus the distortion inevitably lowers the energy resolution even when the line curvature of the signal is corrected for by calculation.…”
Section: Optimization Of Optical Geometry and Grating Parameters Omentioning
confidence: 99%
See 1 more Smart Citation