Proceedings of 1996 IAS Petroleum and Chemical Industry Technical Conference
DOI: 10.1109/pcicon.1996.564867
|View full text |Cite
|
Sign up to set email alerts
|

Design, fabrication, and back-to-back test of 14200 HP, two-pole cylindrical-rotor synchronous motor for ASD application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“…Indeed, one of the first actual applications of a multiphase electric drive was aimed at such an application [218] and it was based on utilization of an asymmetrical six-phase synchronous motor. Highpower multiphase synchronous motors for such applications are usually supplied from current-source thyristor-based 12-pulse LCIs [219], [220]. Typically, two three-phase windings are displaced by 30 • and supplied by two independent threephase LCIs, which receive dc current from two three-phase rectifiers [219].…”
Section: Other Multiphase Motor Drive Solutionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Indeed, one of the first actual applications of a multiphase electric drive was aimed at such an application [218] and it was based on utilization of an asymmetrical six-phase synchronous motor. Highpower multiphase synchronous motors for such applications are usually supplied from current-source thyristor-based 12-pulse LCIs [219], [220]. Typically, two three-phase windings are displaced by 30 • and supplied by two independent threephase LCIs, which receive dc current from two three-phase rectifiers [219].…”
Section: Other Multiphase Motor Drive Solutionsmentioning
confidence: 99%
“…Highpower multiphase synchronous motors for such applications are usually supplied from current-source thyristor-based 12-pulse LCIs [219], [220]. Typically, two three-phase windings are displaced by 30 • and supplied by two independent threephase LCIs, which receive dc current from two three-phase rectifiers [219]. The rectifier input comes from a transformer with star/delta connected dual secondary.…”
Section: Other Multiphase Motor Drive Solutionsmentioning
confidence: 99%
“…This makes it impossible to use a back-toback configuration [2] for the full-load testing. Nevertheless, an assessment of generator operation at full and partial loads is required to validate the design, in particular, regarding rotor thermal behavior.…”
Section: Generation System Descriptionmentioning
confidence: 99%
“…If two or more identical machines are available, full-load factory testing can be performed by resorting to the so-called "back-to-back" configuration [2]. This arrangement, however, is not feasible when only one machine is available.…”
Section: Introductionmentioning
confidence: 99%
“…Generally, it concerns the test where two independent machines are mechanically coupled so that one drives the other [9], [10]. It is also known as Hopkinson's test: two identical machines, coupled to each other, are loaded.…”
Section: Introductionmentioning
confidence: 99%